Pole Mounted Reactive Power Compensation Device

 
 
单价 面议对比
询价 暂无
浏览 216
发货 Chinazhejianghangzhou
库存 50000
过期 长期有效
更新 2020-08-08 09:55
 
联系方式
加关注0

HANGZHOU JINGCHENG ELECTRIC EQUIPMENTS CO., LTD.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Pole Mounted Reactive Power Compensation Device Model NO.: TBBZ10-1200 Filter: Paper Capacitor Tuning: Polystyrene Capacitor Electrolyte: Inorganic Medium Manufacturing Material: Polypropylene Structure: Fixed Capacitor Capacitance: 50-100uf Packaging Type: Surface Mount Application: General Purpose, AC / Motor, Power, High Voltage Type: Polystyrene-film-capacitors Trademark: Jingcheng electric Transport Package: Wooden Book Specification: copper or aluminum Origin: China HS Code: 8532909000 Product Description Technical parameters of pole mounted reactive power compensation device1 OverviewTBBZcolumn type automatic switching high voltage shunt capacitor device (hereinafter referred to as the device) is suitable for 10kV or 6kV distribution line, which is used to improve power factor, reduce line loss and improve voltage quality.The device can be set by the user according to the needs of the line to realize the automatic switching of the shunt capacitor. At the same time, it also has the protection functions of short circuit, over-current, over-voltage and under voltage. The JCZ5 series vacuum contactor adopted has the characteristics of no bounce when closing, no re ignition when opening and long service life; high voltage shunt capacitor with internal fuse and discharge resistance; automatic controller for reactive power compensation has strong anti-interference ability and reliable performance; the device is also equipped with outdoor control power transformer. The device has compact structure and convenient installation.2. Environmental conditions for use2.1 ambient air temperature: upper limit + 45 ºC, lower limit - 40 ºC.2.2 altitude: no more than 1000m.2.3 wind speed: no more than 35m / s.2.4 sunshine: the amplitude (maximum) is 0.1w/cm2.2.5 earthquake: the seismic intensity shall not exceed 8 degrees.2.6 chemical conditions: the installation site is free of harmful gases and vapors, and there is no conductive or explosive dust.3 model meaning and main technical parameters1 Shunt capacitor TBBZ11 - 300 - 3W 12 Arrester 5wr-17 / 4533 Open type current transformer 4 power transformer DC-2 / 10 1 set5 pole voltage and reactive power controller 1 set6 GPRS communication module 1 set of GPRS7vacuum contactor JCZ5-12d / 400A8 protection current transformer 2 sets9 cabinet body (stainless steel plastic spraying) 1 side10 busbar (with color code) TMY 4 × 40 1 set11 composite casing (through wall casing) ZW8-630 3 pieces12 indicator light, micro break and other secondary components 1 set4 structure and working principle4.1 the device consists of full film high voltage shunt capacitor (with discharge resistance and internal fuse), vacuum contactor, voltage transformer, zinc oxide arrester and current transformerSensor, discharge coil, high voltage reactive power compensation controller, protection circuit and hardware.4.2 the device has two types of structure: double pole installation and single pole installation. See attached figure for primary wiring.4.3 working principle4.3.1 the high voltage power supply of the device is connected, and the voltage transformer provides power supply to the automatic controller of high voltage reactive power compensation (hereinafter referred to as the automatic controller) and the operating mechanism of vacuum contactorCurrent 100V power supply. When the voltage, power factor or operation time of the line is within the preset switching range, the automatic controller will connect the power supply of the operating mechanism to close the vacuum contactor and put the capacitor bank into the line operation. When the voltage, power factor or operation time of the line is in the cut-off range, the automatic controller will turn on the power supply of the shunt release to open the vacuum contactor and exit the operation of the capacitor bank. Thus the automatic switching of capacitor is realized, the purpose of improving power factor, reducing line loss and improving voltage quality is achieved, and reactive power reverse transmission is prevented at the same time.4.3.2When the line voltage is higher than the setting value of overvoltage protection (1.1 ~ 1.3un), the automatic controller will delay 30s to trip the vacuum contactor and the capacitor will be out of operation.Within the delay time, the line voltage returns to normal and the switch does not trip. After the switch trips, when the line voltage returns to normal, the automatic controller delays for 10 minutes to close the switch.
举报收藏 0
更多>本企业其它产品
Power Factor Controller Microcomputer Protection Unit High-Voltage Reactive Powercompensation Controller Controller of Capacitor Bank 35kv Series Reactor 35kv Series Epoxy Cast Dry Core Reactor 35kv Shunt Capacitor Bank High Voltage Shunt Capacitor
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报