Yuyao Gongyi Meter Co. Ltd. Xmta-908t Temperature and Timer Meter

 
 
单价 25.80 / Piece对比
销量 暂无
浏览 35
发货 Chinajiangxijian
库存 100000Piece
过期 长期有效
更新 2020-04-23 05:04
 
联系方式
加关注0

Yuyao Gongyi Meter Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Yuyao Gongyi Meter Co., Ltd. Xmta-908t Temperature and Timer Meter Model NO.: XMTA-908T Display Type: LED Certification: CE Customized: Customized Size: 96*96 Trademark: CJ Transport Package: 1PCS/Box Specification: ISO 9001: 2008 Others Origin: China HS Code: 9032900090 Product Description Product DescriptionSpecificationsTemperature controllerPIDintelligence dual row 4-LED displaysdisplaying the measured value and set value.Main technical specification1. Measurement deviation: ≤ ± 0.5%F. S± 1B2. Cold end compensating deviation: ≤ ± 2.0C3. Sampling cycle: 0.5S4. Control cycle: Relay output 2-120S, other is 2S.5. Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A(perceptualLoad)6. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contactpulse7. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V.8. Continuous PID: 0-10mA (load 500± 200Ω ), 4-20mA (load 250± 100Ω ), or 0-5V(load≥ 100kΩ ), 1-5V (load≥ 100kΩ )9. Exterior and hole size(mm): 96× 96× 110 92× 9210. Power: AC85V242V, 50/60Hz11. Working condition: Temperature 0-50.0C, relative humidity≤ 85%RH, without corrodeand strong electric radiation.Panel instruction(consult)Connection scheme(consult)Model code XMT ( ) - 9 ( ) 8 ( ) 1 2 3 4 51:The surface dimension (mm)Blank: 160×80×85 Installation hole 156×76 A: 96×96×80 Installation hole 92×92D: 72×72×80 Installation hole 68×68 E: 48×96×75 Installation hole 44×92F: 96×48×75 Installation hole 92×44 G: 48×48×110 Installation hole 44×44S: 80×160×85 Installation hole 76×1562: Operation display method:'9' 4-key gentle push-switch setting,double row 4-LED digital display,PID and ON/OFF(P=0)control can select.3:Additional alarm:'1' No over-temperature alarm, but a group of time control output;'3' A group of alarm ( upper limit alarm or follow-up alarm ) and a group of time-control relay output;'5' No over-temperature alarm, but a group of time control output for buzzer alarm .4:Input: '8' input signal can interchange free(no voltage and current input)5:Suffix Blank:relay output G:solid relay output T:Time control functionInner parameterSeriesCodeNameSetting rangeManualEx-Factory0SPSetting value of temperatureDetermined by P-SL P-SHOutput corresponds to "OUT" indicator light50.01AL1Alarm 1Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarmplease refer to ALP1Corresponds to "ALM1" indicator light3002AL2Alarm 2please refer to ALP2Corresponds to "ALM2" indicator light1003PProportion modulus0~100When the P↑, the proportion and differentialfunction↓; If the P↓, the proportion anddifferential function↑When P=0, the meter is ON/OFF control154ICalculus time0~2000S2405dDifferential time0~200S306AtSetting itselfON/OFFON: open setting itself functionOFF: close setting itself functionOFF7tControl period1~120SThe movements cycle ON/OFF of Setting relays control is no meaning,Relay is 20S, other is 2S.208HyMain control bydrop in level0.1~50.0only have meaning when main control output is ON/OFF(P=0)1.09Hy-1drop in levelof AL10.1~50.0It is used as setting of drop in levelfor AL1 relay output 1.010Hy-2drop in levelof AL20.1~50.0It is used as setting of drop in levelfor AL2 relay output1.011PbSensor error amendment±20.0The sensor have deviation can use item to revisal012FILTFilt modulus0~50Is the software filter constants of measurement sampling. The constant ↑, the measurements antijamming capability↑, but the measurement and system time ↓.2013dpDisplay precision0~11: have radix point; 0: have not radix point014P-SHThe max.value of temperature range-They are used to reset proper temperature range as per user'application.As for the Max. temperature range fordifferent inputs, please refer to Sn,P-SH≥P-SL130015P-SLThe min.value of temperature range-016OUTLThe min. valueof allowable output 0~OUTHCan achieve low and high output limiter. Meaningless when manual and ON/OFF control017OUTHThe max. valueof allowable outputOUTL~20020018ALP1Alarm1 and output definition0~4'o':indicate no alarm; '1':upper limit alarm'2':lower limit alarm;'3': Upper-limit (deviation) Alarm;'4': Lower-limit (deviation) Alarm;-19ALP2Alarm2 and output definition0~4-20COOLSystem function choice0~1'0': reverse control(heat)'1': positive control(cool)021OPPOOpen power output0~100Soft start functionthat meters coefficient after first export of electric power022LOCKCode lock0~50LOCK=0, all the parameter can be revisedLOCK=1, only the SP can be revisedLOCK>1, all the parameter can not be revised023SnInput typeCU50( )PT100( )PT100( )K( ),E( ),J( )T( ),S( )CU50 (-50.0~150.0ºC) ;PT1 (-200.0~200.0ºC) ;PT2 (-200.0~600.0ºC) ;K (0~1300ºC) ;E (0~700.0ºC) ; J (0~900.0ºC) ;T (-200~400.0ºC) ; S (0~1600ºC) ;24OP-AOutput typeRLP( )SSR( )Zero( )Mut( )0~10MA( )4~20MA( )RLP Relay output modeSSR Solid state relayZero SCR zero voltage switchingMut SCR phase-shift trigger0~10MA linearity control electric current output4~20MA linearity control electric current output__
举报收藏 0
更多>本企业其它产品
Big-Screen Temperature and Humidity Meter for Wood Processing Sites Yuyao Gongyi Cj Te-01 Electronic Temperature Control Meter EU-08 Digital Temperature Display/Control Instrument Xmta-618t Cj Temperature and Time Control Meter Small Thermocouple/Thermal Resistance (screw sensor) for Package Temperature Sensor (pressure type) for Industry Temperature Sensor Thermocouple (Tube Sensor) Temperature Sensor (Simple Sensor) for Industrial
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报