详细说明
Product Name: XLPE Insulated Electric Cable - Rated Voltage 3.6/6kv-26/35kv Model NO.: YJV, YJY Brand: Santai Model: YJV Certification: ISO, CCC, CE, RoHS Wire Core Material: Bare Copper Wire Material Shape: Round Wire Sheath Material: PVC Insulation Material: XLPE Current: AC Cable Voltage: Low and Medium Voltage Cable Application: Construction, Underground, Industrial, Power Station Trademark: SANTAI Origin: Taizhou HS Code: 8544601200 Product Description XLPE Insulated Electric Cable -- Rated voltage 3.6/6KV-26/35KVCable construction: , Model, Name & Application:ModelNameApplicationYJV,Copper conductor,XLPE insulated,PVC sheathed electric cable,.For laying indoors,in tunnels,cable trench,etc,unable to bear external mechanical forces..Single core cable in magnetic duct is not permissible.YJLV,Aluminium conductor,XLPE insulated,PVC sheathed electric cableYJY,Copper conductor,XLPE insulated,PE sheathed electric cableYJLY,Aluminium conductor,XLPE insulated,PE sheathed electric cableYJV22,Copper conductor,XLPE insulated,Steel tape armoured,PVC sheathed electric cable,,.For laying indoors,in tunnels,cable trench,or direct in ground..Able to bear external mechanical forces,but unable to bear large pulling forces.YJLV22,Aluminium conductor,XLPE insulated,Steel tape armoured,PVC sheathed electric cableYJV23,Copper conductor,XLPE insulated,Steel tape armoured,PE sheathed electric cableYJLV23,Aluminium conductor,XLPE insulated,Steel tape armoured,PE sheathed electric cableYJV32,Copper conductor,XLPE insulated,Steel wire armoured,PVC sheathed electric cable,,,.For laying indoors,in tunnels,cable trench,vertical shaft or direct in ground..Able to bear external mechanical forces and some pulling forces.YJLV32,Aluminium conductor,XLPE insulated,Steel wire armoured,PVC sheathed electric cableYJV33,Copper conductor,XLPE insulated,Steel wire armoured,PE sheathed electric cableYJLV33,Aluminium conductor,XLPE insulated,Steel wire armoured,PE sheathed electric cableProduct data:3.6/6KV, , /3.6/6KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×252.5 17.956039021.770055024.7134011901×352.5 18.968048022.682061025.8149012901×502.5 20.386055024.099069027.2172014201×702.5 21.9108065025.4122079028.8201015901×952.5 23.7135076027.2149092030.6235017701×1202.5 25.2161087028.71770104032.1268019501×1502.5 27.0192099031.72240133034.9307021601×1852.5 28.62290114033.32600148036.5348023601×2402.6 31.22860137035.93180173039.1414026801×3002.8 34.03500164038.73810199041.9484030201×4003.037.64610214042.54840242045.6632038901×5003.241.35700261046.35860283049.3747044401×6303.244.96990309050.07200338053.1894051203.6/6KV, , /3.6/6KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×252.5 35.81750128040.52760230042.7362031603×352.5 38.12130147043.03210255046.2414034903×502.5 41.12670174046.13830289049.3486039403×702.5 44.53390209049.74650334052.9577044803×952.5 48.54250247053.85630385057.0687051203×1202.5 51.75090285057.26550431060.4787056503×1502.5 55.46120331060.97650484064.2909063203×1852.5 58.87270380064.58890543067.81046070503×2402.6 64.69090460070.510860637075.11338089403×3002.8 70.611120551076.713230761081.315680101303×4003.078.415190775086.2178301044089.519320119303×5003.286.217131804594.3200871125697.623060138203×6303.294.0210379749102.42395213166105.727690160506/6 6/10KV, , /6/6 6/10KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×253.4 19.860945823.491976726.6164313841×353.4 20.872951424.4105584027.6182114991×503.422.387658525.7121992929.1202716281×703.4 23.8109268127.21458104730.6232918101×953.4 25.7138880529.11780119732.5268919991×1203.427.1165191331.92312157533.9303721921×1503.4 28.71970104333.52670174335.7341923841×1853.4 30.42271116535.23007190138.4414728691×2403.432.92830138237.73621217340.9484232221×3003.4 35.33502164239.94330247043.3563736061×4003.4 38.54406199143.35281286646.7670141151×5003.442.05515241847.06442334550.2799247241×6303.445.66754288350.87766389554.0945754146/6 6/10KV, , /6/6 6/10KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×253.4 39.81927145144.82785232248.0422937663×353.4 42.22136163947.43224256950.6477141173×503.445.22805187450.43795290953.6545645713×703.4 48.63497219354.04586333557.2635251013×953.4 52.74483265357.95631385761.1753957653×1203.455.95340304061.36561431764.5857863343×1503.4 59.66398350365.47732491168.6990170803×1853.4 63.07241394668.88828546072.01109577273×2403.468.39234472974.310769636077.51325488443×3003.4 73.311337558680.913069740684.216678110153×4003.4 80.314174682288.116832948091.420051126983×5003.487.917730829995.2206871125699.224211147803×6303.495.8217369949104.02495213165107.328839170528.7/10 8.7/15KV, , /8.7/10 8.7/15KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×254.5 22.069654425.691976729.0184615871×354.5 23.081960426.6105584030.0202617041×504.524.597067927.9121992931.5223718391×704.5 26.2119178030.81458104733.0252020021×954.5 27.9149391032.71780119734.9291122201×1204.529.51760102334.12312157537.5369027701×1504.5 31.12085115835.92670174339.1400529071×1854.5 32.82391128537.63007190140.8440231241×2404.535.32873152539.93621217343.1510434851×3004.5 37.73657179842.54330247045.7590838771×4004.5 40.94571215645.75281286648.9698243961×5004.544.45692259549.46442334552.6828750181×6304.548.06945307453.47766389556.6978957468.7/10 8.7/15KV, , /8.7/10 8.7/15KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×254.5 45.02917174750.23201273952.4484143783×354.5 47.32616194752.33646299155.7539447403×504.550.33144222355.74269338358.9610752223×704.5 53.83879258659.45082383162.6706658153×954.5 57.64872305163.26159428566.4827665013×1204.560.95753345866.77115487069.9931270683×1504.5 64.56837394570.58296547573.71063678143×1854.5 68.17900442974.19429606177.31187985103×2404.573.39719523079.511450704184.215060106503×3004.5 78.411862615486.214508884589.517597119343×4004.5 85.314795740293.5176951034396.821109137563×5004.593.0183818950101.22150312072104.525267158363×6304.5100.72239610609109.32586914082112.6298921810512/20KV, , /12/20KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×355.5 25.493072030.11410120032.2203018201×505.526.8116085031.51630132033.6228019801×705.5 28.4141098033.11890146035.2258021501×955.5 30.21690111034.92210164037.0295023701×1205.531.71980124036.42510178038.5328025501×1505.5 33.42310138038.12880197040.2368027701×1855.5 35.02700155039.73270215041.8411029901×2405.537.43290180042.13900244045.4515036901×3005.5 39.83910205044.74590277047.9593041101×4005.5 43.05030255048.15670325051.3713046901×5005.546.26120303051.46760373054.6832052801×6305.5 49.87440354055.28150432058.49830601012/20KV, , /12/20KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×355.5 52.03230257057.44270362060.7597053303×505.555.03840290060.64930401063.8673058103×705.5 58.14640333064.15830454067.3772064303×955.5 62.35570380068.26850509072.8964078903×1205.565.66480424071.57850564076.11080085803×1505.5 69.27560475075.39040626079.91218094103×1855.5 72.78780532078.910300689083.513600101803×2405.578.010680618085.713120869089.015850114203×3005.5 83.012720710091.015350981094.318260127203×4005.5 90.016280879098.21894011560101.522100147103×5005.596.8188209580105.32253013300108.625950167103×6305.5 104.62295011310113.42700015370116.7306901905018/20 18/30KV, , /18/20 18/30KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×358.031.912401020------1×508.033.31560125035.42060176038.8291026101×708.0 34.91840140038.62340191040.7324028201×958.036.72140155040.12680210042.3361030301×1208.038.22450170041.83020229043.9437036401×1508.0 39.92790186043.43400249046.7481039001×1858.041.53200205045.33810269048.5527041501×2408.044.03800231047.64490303050.7604045801×3008.0 46.34460260050.25180330053.5681049901×4008.049.65530306053.46310388056.7805056201×5008.052.86160356057.07430439060.3928062501×6308.0 56.48020412061.28860503064.310830701018/20 18/30KV, , /18/20 18/30KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×508.068.45290435075.17200625079.7979088703×708.0 72.56240493078.78230691083.31090096103×958.075.97360558084.09410762087.412220104703×1208.079.48350610087.511120887090.813440112203×1508.0 82.69520641091.312400958094.614880121003×1858.084.410830737094.9139101045098.216420129903×2408.091.4128108300100.31608011590103.718770143403×3008.0 96.7149209300105.61850012850108.921250157103×4008.0103.81811010620112.82192014410116.125260178703×5008.0111.12099011780119.32597016330123.229260200303×6308.0 119.22529013650128.93125018970131.3341702253021/35KV, , /21/35KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×509.336.11590129040.52370207043.0320028901×709.3 37.71840142042.22670225045.7392034901×959.339.52160158044.13030246047.6434037601×1209.341.02450172045.63350262049.1471039801×1509.3 42.72810189047.43750284050.9516042501×1859.344.33190207049.04190306052.6566045301×2409.346.73810235051.64860340055.1640049501×3009.3 49.14460264054.15590377057.6722053901×4009.352.35510308057.46710428061.0844060201×5009.3 55.56570354060.77870484064.2972066901×6309.359.17910408064.49290547068.011260744021/35KV, , /21/35KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×509.375.15560464082.78260734086.01089099603×709.3 78.66450516086.39280799089.612030107403×959.382.57490573090.410500874093.713430116703×1209.385.78470626093.711630942097.014630124203×1509.3 89.49640686097.51297010200100.816100133303×1859.392.8109207500101.11442011010104.417680142603×2409.398.1129508520106.61669012260109.920140157103×3009.3 103.1150609520111.81899013450115.122610170703×4009.3110.11852011120119.02282015430122.326680192903×5009.3 116.92199012760126.12663017390129.430750215203×6309.3124.72635014710134.23134019700137.5357302409026/35KV, , /26/35KV, 1-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV331×5010.538.71727142743.72600232046.9403034901×7010.5 40.21980157045.22890248048.4438037101×9510.542.12335175047.13270269050.3483039901×12010.5 43.72650191048.73600286051.9525042601×15010.545.33016209050.54020309053.7573045401×18510.5 47.03377227052.04410330555.2616047901×24010.549.33996255054.75110366057.9694052301×30010.5 51.74733287057.15900404060.3781056901×40010.554.95723330860.56340452063.7899063101×50010.5 59.87068397065.68380529068.81050071401×63010.563.68418455069.29790591072.612080795026/35KV, , /26/35KV, 3-Core XLPE Insulated, PVC/PE Sheathed Power CableNominal cross-sectional area of conductor (mm2)Insulation thickness (mm)YJV, YJLV, YJY, YJLYYJV22, YJLV22, YJV23, YJLV23YJV32,YJLV32,YJV33,YJLV33Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)Approx. overall diameter of cable (mm)Approx. weight of cable (kg/km)YJV, YJYYJLV, YJLYYJV22, YJV23YJLV22, YJLV23YJV32, YJV33YJLV32, YJLV333×5010.580.86030515088.68700782091.912620117403×7010.5 84.26900565092.09690843095.513820125603×9510.588.18060628286.311050927099.615360135903×12010.5 91.39070683099.7122109970103.016700144603×15010.594.9102907470103.31356010730106.618280154603×18510.5 98.4114908120107.01488011500110.019595163353×24010.5103.5135509140112.51721012800115.222105178203×30010.5 108.71595010290117.71976014100120.825360202803×40010.5115.51918011830125.12339016080127.83158025050Technical data: Max. DC resistance & short circuit current of conductorNominal cross- sectional area of conductor (mm2)20ºC (Ω/KM)Max. DC resistance of conductor @ 20ºC90ºC (1)Max. Short circuit current of conductor (1s) @ 90ºCCopper conductorAluminum conductorCopper conductorAluminum conductor250.7271.203.582.36350.5240.8685.013.31500.3870.6417.154.72700.2680.44310.026.61950.1930.32013.598.981200.1530.25317.1711.341500.1240.20621.4614.3171850.09910.16426.4715.482400.07540.12534.622.683000.06010.10042.9328.354000.04700.077857.2337.795000.03660.060574.5147.246300.02830.046990.1459.52, Voltage test & Partial discharge testNo.Test itemsRated voltage (KV)3.6/66/66/108.7/108.7/1512/2018/2018/3021/3526/351(kv/5min)Power frequency AC voltage test12.52130.5426373.59124AC voltage test for 4 hours (kV)14.424354872841043Impulse voltage test (kV)60759512517020020041.73U010PCPartial discharge at 1.73U0 voltage should not exceed 10 PCPassPassPassPassPassPassPass Current carrying capacity of CableConductorNominal cross- sectional area of conductor (mm2)3.6/6-12/20KV18/20-26/35KVIn the airUndergroundIn the airUndergroundSingle-core3-coreSingle-core3-coreSingle-core3-coreSingle-core3-coreCopper conductor25140120150125----35170140180155----502051652151802151802151907026021026522027022026523095315255315265330265315275120360290360300380305360315150410330405340430345400355185470375455380490390455400240555435530435575455525460300640495595485660525595520400745565680520765600680590500855-765-875-775-630980-860-1010-875-Aluminum conductor2511090115100----35135110135120----501601301601401701401651457020016520017021017020018095245200240210255205240215120280225270235295235270246150320255305260330270305275185365295345300380305345310240435345400345450355400360300500390455390515410455410400585450520440600470525465500680-595-695-600-630790-680-810-685-Installation and operation condition of cable: Max. operating temperature of conductor:90ºCAmbient temperature in air:40ºCSoil temperature: 25ºCSoil thermal resitivity: 1.0ºCm/WLaying depth: 0.8mSingle-Circuit only,. Single-core cable is installed in parallel. Adjacent space is equivalent to the diameter of the cable. 0ºC.The ambient temperature under installation should not below 0ºC.Conversion factors of current rating for different ambient temperature :Air temperature20ºC25ºC30ºC35ºC40ºC45ºC50ºCConversion factor1.181.141.101.051.000.950.89Soil temperature15ºC20ºC25ºC30ºC35ºC40ºC45ºCConversion factor1.071.041.000.960.920.870.83