Wst 30/20-6X5s Strip Form Tap Changer for Transformer with New Hand Wheel

 
 
单价 6.00 / Pieces对比
销量 暂无
浏览 266
发货 Chinatianjin
库存 35000Pieces
过期 长期有效
更新 2020-08-08 10:10
 
联系方式
加关注0

XIN CHENG INDUSTRY MATERIAL CO., LTD.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Wst 30/20-6X5s Strip Form Tap Changer for Transformer with New Hand Wheel Model NO.: WST 30/20-6X5S Strip Form Tap Changer for Transfor Product Name: off Circuit Tap Changer Model Number: Model Number: W_ T_ Rated Current: Under 500A Max. Voltage: 10-35kv, 35kv Regulation: 2.5% Per Position Type: off Load Function: Voltage Regulating Phase Type: Three or Single Usage: Oil Immersed Distribution Transformer & Power Tran Regulating Position1: Neutral/Central/Terminal Regulating Position2: Y-Triangle Conversion/ Series-Parallel Connection Mechanical Life: 20000times Supply Ability: 35000 Piece/Pieces Per Month Trademark: XINCHENG Transport Package: Pallet Specification: PIECE Origin: China Product Description Quick DetailsPlace of Origin: China (Mainland) Brand Name: XINCHENGProduct name: off circuit tap changer Model Number: W_ T_Rated current: Under 500A Max. Voltage: 10-35KV, 35KVRegulation: 2.5% per position Type: Off LoadFunction: Voltage Regulating Phase Type: Three or singleGrade No.: 3- 9different as different product Tapping position: 5-7-8 different as different productUsage: oil immersed distribution transformer &power transformerRegulating Position1: Neutral/Central/TerminalRegulating Position2: Y-Triangle conversion/ series-parallel connection Mechanical Life: 20000timesSupply Ability: 35000 Piece/Pieces per MonthNon-excitation tap switch applies to oil-immersed transformer with 50Hz or 60Hz of rated frequency. In case of no excitation in transformer (i.e. no winding is charged), the switch can be operated manually or electrically to change the tapping position and further to change the transformation ratio, and by this means, secondary voltage can be adjusted or stabilized.Specific introduction:This series of switches is composed of the main body of the switch and the operation turning organ. They are applicable to the oil-immersed transformers with the frequency of 50Hz, 60Hz. They ca be fixed on the body of the transformer or on the box-cover, and be tapped, regulated and changed under on excitation condition.1.This kind of electric off circuit tap changer applies to the single-phase, three-phase, combination oil-immersed transformer of electrical power .2.The frequency of 50HZ,60HZ,rated voltage of 10KV,35KV,rated current of 30A~250A;the voltage-regulating places are: central part, neutralpoint, can be directly fixed on the box-cover of the transformer3.under the non-excitation condition regulating and changing.4.power deviceChinese manufacturer off circuit tap changerWST series off-circuit off load tap changer for transformerThis kind of switch applies to the single-phase, three phase, combination oil-immersed transformer electrical power with frequency of 50Hz,60Hz, rated voltage of 10KV,35KV, rated current of 30A~500A; the voltage-regulating mode are central part, terminal point and neutral point, which can be directly fixed on the tank cover of the transformer and exchanged under the off-circuit condition.Non-excitation strip Tap Changer for voltage regulator :This kind of switch applies to the single-phase, three phase, combination oil-immersed transformer electrical power with frequency of 50HZ,60HZ,rated voltage of 10KV,35KV,rated current of 30A~500A;the voltage-regulating mode are: central part, terminal point neutral point, which can be directly fixed on the tank cover of the transformer, exchange under the off-circuit condition.Technical data:SpecificationsWST 30WST 63WST 125WST 250WST 400WST 500Phase number three-phasesConnection mode(2) (3) (1)Central point(2)Neutral Point(3)Terminal Point(1)Rated through current(A)30631252504005000.71.62.53.7545Short-circuit capacityHeat stableness current(KA/2s)1.846.259.3751012.5Dynamic stableness current(KA) Rated frequency50~60(KV)Rated Voltage10KV20KV35KVInsulation level(KV)Power-frequency withstand Voltage(50Hz/1min)42KV55KV95KVImpulse(1.2/50μs)75KV125KV250KVSealing Performance(KPa/24h)60Machine life(Thousands of times)2Our other product series:WST series off-circuit off load tap changer for transformerThis kind of switch applies to the single-phase, three phase, combination oil-immersed transformer electrical power with frequency of 50Hz,60Hz, rated voltage of 10KV,35KV, rated current of 30A~500A; the voltage-regulating mode are central part, terminal point and neutral point, which can be directly fixed on the tank cover of the transformer and exchanged under the off-circuit condition.Off-circuit Single Phase Linear Tap Changer-Used in mineral oil or silicon oil -Used in mineral oil or silicon oil-Rated voltage 10KV-35KV -Rated voltage 10KV-24KV-Rated current from 63A-250A -Rated current from 30A-63A-Tapping position:3-7 -Tapping position:3-7-Regulation 2.5% per position -Regulation 2.5% per positionOff-circuit Three Phase Linear Tap Changer-Used in mineral oil or silicon oil -Used in mineral oil or silicon oil-Rated voltage 10KV-35KV -Rated voltage 10KV-35KV-Rated current from 63A-300A -Rated current from 63A-250A-Tapping position:3-9 -Tapping position:3-7-Regulation 2.5% per position -Regulation 2.5% per positionOff-circuit Combination Linear Type (ZH2)Three Phase Linear Tap Changer-Used in mineral oil or silicon oil-Rated voltage 10KV-35KV-Rated current from 63A-250A-Tapping position:3-5-Regulation 2.5% per positionOff-circuit Combination Linear Type (ZH3)Three Phase Linear Tap Changer-Used in mineral oil or silicon oil-Rated voltage 20KV-Rated current from 63A-250A-Tapping position:3-5-Regulation 2.5% per positionFAQ1. Can you offer test report of the product?A: We test every product before packing and delivery. Test report will be provided by requirement.2. Can you offer components of the products?A: Yes, we also sell components separately too.3. Shall we pay for the sample charges? How to pay and how to deliver us?A: For low cost samples, we providing with FOC, customer need to pay for the freight through Western Union etc or providing with freight collection account of courier like DHL, THT, FedEx, the sample will be sent by courier.4. Could you manufacture the products according to my drawing or sample?A: Yes, ODM is available, we also could manufacture the products according to customer's drawing or replicate sample.5. If new mould is needed, shall we pay for the mould cost? If mould cost will be refunded?A: Yes, customer will be asked to pay for the mould cost, this mould cost will be deducted gradually from your orders.6. More questionA:Feel free to contact me, you will get immediately replyPackaging &DeliveryPackaging Details standard export packing Carton Box +Wooden PalletDelivery Time 2-4 weeks upon depositPort: Tianjin, Shanghai, QingdaoPlease Contact UsMiss: lydiaMob: 86-13752439076 Fax: 86-22-60863016 http://www.chinainsulatingmaterial.com
举报收藏 0
更多>本企业其它产品
1050/1060/1350 Aluminum Busbar for Transformers Highly Flexible Copper Foil Soft Connectors for Electrical Transformers Parts Series Specification Soft Electrical Busbar Connectors Fr4 Rectangular Nuts (yellow) for Transformer Fixing/G10 Nuts/ G10 Bolts Bkl Tube for Transformer/Distribution Transformer Insulation Tube/Bakelite Tube Epoxy Diamond Dotted Insulation Paper (DDP paper) /Insulation Paper/Heat Insulation Material  Even 1 Customized 15mm to 1650mm Mylar 6021 Milky White Pet Polyester Film Electrical Insulation Material I DMD Film for Transformer Winding
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报