Tyco D3 K33.1 125 Degree Medium Velocity Bronze Open Spray Nozzles

 
 
单价 17.00 / Pieces对比
销量 暂无
浏览 235
发货 Chinahunanzhuzhou
库存 100000000Pieces
过期 长期有效
更新 2020-08-04 05:20
 
联系方式
加关注0

Qingdao Kingworld Control Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Tyco D3 K33.1 125 Degree Medium Velocity Bronze Open Spray Nozzles Model NO.: D3 Nozzle Flow Coefficient: 33.1 Dry Alarm Valve Type: Enclosed Type Closed Fire Sprinkler System: Wet Fire Sprinkler System Open Fire Sprinkler System Type: Deluge System Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed Alarm Valve Type: Deluge Valve Sprinkler Head Type: Open Sprinkler Installation: Pendent Certificate: UL FM Material: Brass Trademark: TYCO Transport Package: Packing Export Standard Specification: 125 degree Origin: UK Product Description Tyco D3 k33.1 125 degree medium velocity bronze open spray nozzlesThe TYCO Type D3 PROTECTO-SPRAY Nozzles are open (non-auto-matic) directional spray nozzles and they are designed for use in water spray fixed systems for fire protection applications. They are external deflec-tor type nozzles that discharge a uni-formly filled cone of medium velocity water droplets.The D3 Nozzles are effective in cov-ering exposed vertical, horizontal, curved, and irregular shaped surfaces in a cooling spray to prevent exces-sive absorption of heat from an exter-nal fire and possible structural dam-age or spread of fire to the protected equipment. In some applications, de-pending on water design density re-quirements, the Type D3 Nozzles may also be used for fire control or extinguishment.The Type D3 Nozzles are available in a wide variety of orifice sizes and spray angles (included angle of discharge)­to provide versatility in system design. Refer to Technical Data Sheet TFP890 for information on Blow-Off Plugs that can be used for applications where protection is required against insect infestation or accumulation of debris within the nozzle orifice.It is recommended that the end user be consulted with respect to the suit-ability of the materials of construc-tion and finish for any given corrosive environment­. The effects of ambient temperature,­ concentration of chem-icals, and gas/chemical velocity,should be considered, at a minimum, along with the corrosive nature to which the sprinklers­ may be exposed.The Type D3 PROTECTOSPRAY Noz-zle is a re-designation for the Gem Type D3.Design CriteriaNozzle Placement. Where direct im-pingement of water spray onto all of the protected surface is required by the authority having jurisdiction, the nozzles are to be spaced and directed so that their spray patterns will com-pletely cover the plane-of-protection with the minimum required average density; however, it is recommend-ed that indoor nozzle spacing be 12 feet (3,7 m) or less and that outdoor nozzle spacing be 10 feet (3,0 m) or less. Where rundown or slippage is planned, such as, exposure protec-tion of vessels per NFPA 15, the above recommended­ indoor and outdoor spacings­ also apply.When used for protecting the surfaces of a vessel, for example, the nozzles are positioned normal to and approxi-mately 2 feet (0,6 m) from the surface. This approach, in conjunction with a properly selected spray angle, will tend to make more effective use of the spray as well as help minimize the dis-turbance effects of wind/draft condi-tions on the water spray patterns.Spray Patterns. The Design SprayProfiles for the nozzle spray angles of 65 to 180 degrees are shown in Fig-ure 2 and apply to discharge pres-sures of 20 to 60 psi (1,4 to 4,1 bar). Discharge pressures in excess of 60 psi (4,1 bar) will result in a decrease in coverage area since the spray pat-terns tend to draw inwards at higher pressures. Refer inquiries on higher discharge pressures to the Technical Services Department. The maximum axial distances between the nozzle tip and plane-of-protection, for exposure.
举报收藏 0
更多>本企业其它产品
Potter Brand FM UL Water Flow Detector Flow Switch 1144402 Osysu-1 Outside Screw and Yoke Valve Supervisory Switch 101 0102 Potter Saddle Type Flow Sensor Flow Detector 1144402 Tyco G1 G2 UL FM Sprinkler Guard for Fire Sprinkler/ Sprinkler Guard Tyco UL/FM Two-Piece Recessed Escutcheons Plate for Fire Sprinkler Escutcheons Tyco Brand Warehouse Sprinkler Esfr Type Ty6226 Model FM TYCO ESFR-14 K242 UPRIGHT WAREHOUSE SPRINKLER Tyco Ashcroft UL FM Fire Protection Sprinkler Pressure Gauge
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报