Supplier
Buyer
Help
Apps
Rules

Tp MCCB 100A Moulded Case Circuit Breaker

 
 
单价 $1.00 / Pieces对比
销量 暂无
浏览 191
发货 Chinazhejiangwenzhou
库存 500000Pieces
过期 长期有效
更新 2020-08-18 05:15
 
联系方式
加关注0

Gret Electric Co., Ltd.

Unverified第7年
资料未认证
保证金未缴纳
详细说明
Product Name: Tp MCCB 100A Moulded Case Circuit Breaker Model NO.: GDM15-100/390 100A Certification: ISO9001-2000, CE, CCC Function: Conventional Circuit Breaker Type: Circuit Breaker Poles Number: 3 Structure: MCCB Installation: Fixed Arc-extinguishing Medium: Air Speed: Normal Type Circuit Breaker Operation: Manual Type Breaking Capacity: Low Voltage Circuit Breakers Category: a Rated Current: 100A Rated Voltage: 220/380 Rated Insulation Voltage: 690V Shell Material: Bakelite Contact Point: Silver Alloy, Silver,Copper Product Name: MCCB Trademark: GRET/ODM/OEM Transport Package: Carton Specification: frame Size 800 Origin: China HS Code: 853620 Product Description DescriptionGDM15 series mould case circuit breaker(hereinafter referred to as circuit breaker)is mainly used for overload and short circuit protection of power distribution and motor in AC 50Hz circuit with rated voltage of 220V or 380V and rated current up to 100A,it can be used for infrequent transfer of circuit and infrequent start of motorNormal service condition1.The altitude of the installtion site shall not exceed 20000m.2.Ambient air temperature:the ambient temperature shall not exceed+40ºC;the ambient air temperature shall not be less than-5ºC;the average value shall not exceed+35ºCwithin 24hours;3.Atmosphere condition:The relative humidity of atmospher shall not exceed 50% at highest temperature of +40ºC,and it can be higher at a lower temperature,when the average lowest temperature in the wettest month doesn't exceed 25ºC then the average highest relative humidity of the present month shall not exceed 90%,condensation on product surface due to temperatuyre change must be taken into account.4.Installation condition:It shall be installed in place where there is no shock vibration and no effect from rain and snow,and the upper connection terminal shall be connected with power supply side while the lower connection terminal shall be connected with load side,where the inclination to vertical surface does not exceed 5°5.The installation class is class III6.The pollution level is class 3Technical DateModleRated current of frame(A)Rated voltage(V)Number of polesRated current(A)GDM15-404022016/10/16/20/25/32/40220238033804GDM15-100220210/16/20/25/32/40/50/63/80/10038033804The rated short circuit breaking capacity shall not be lower than the regulation of following tableRated cuurent of frame(A)Rated limiting short circuit breaking capacity(Icu)kATest voltagePower factor(cosφ)Arcing distance(mm)403kA1.05Un0.9≤501005kA1.05Un0.7≤70The test parameter for the number of operation cycles shall comply with the regulation of following table.Type of protectionOn load operationRated current of frame(A)Number of operation cyclesOperationMakeBreakCOSφOn-loadNo-loadTotalNumber of cyclesFor motor protectionUn 6In0.17Un 6In0.3540/1001500850010000120/hFor power distributionUn InUn In0.840/1001500850010000120/hProduct picsMore Product
举报收藏 0
>本企业其它产品
230V 2 Poles Single Phase Residual Current Device RCD RCCB ELCB Low Current 230V/400VAC 9-95A AC Contactor Conductive 4 Pole 32A AC220V 3201 Magnetic Telemecanique Type Contactor 330 AMPS 220/380V AC Contactor  Electric Magnetic Contactor for Elevator LC1-D25f7 3p+Nc+No Magnetic Electric AC Contactor Hr6-630 Fuse Type Disconnectors Knife Switch AC220V 40A 22kw Load Electromagnetic Electrical Contactor 3p 4p LC1d09 LC1d12 LC1d18 LC1d25 LC1d32 AC220V Magnetic Contactor