Surgical Ultracision Harmonic Scalpel Compatible with Ethicon Gen11 HP054 Har36

 
 
单价 5.00 / Piece对比
销量 暂无
浏览 219
发货 Chinazhejianghangzhou
库存 1000Piece
过期 长期有效
更新 2020-05-16 22:23
 
联系方式
加关注0

Hangzhou EndoTop Medi-Tech Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Surgical Ultracision Harmonic Scalpel Compatible with Ethicon Gen11 HP054 Har36 Model NO.: UHS14 Group: All Certification: CE, ISO13485 Feature: Disposable, Reusable Material: Steel Application: Orthopedic, Abdominal, Ent, Neurosurgery, Microsurgery, Anorectal, Urology Type: Scalpel Power Level: Min and Max Transport Package: Carton Origin: China HS Code: 9018909011 Product Description System DescriptionThe UHS14 System utilizes ultrasonic energy to enable haemostatic cutting and/or coagulation of soft tissue. The system consists of an ultrasonic generator, a foot switch, an optional hand switching adaptor, a hand piece, and a variety of open and minimally invasive instruments.Hand Piece Scalpel ENDOHP36/ENDOHP23/ENDOHP14Foot Switch ENDOFS00Ultrasonic Scalpel System UHE14The instruments vibrate longitudinally at 55.5 kilohertz. This ultrasonic vibration at the blade enhances its cutting ability. The same vibration seals small vessels with coagulated blood and tissue proteins. Haemostasis occurs when tissue couples with the instrument. This coupling causes collagen molecules within the tissue to vibrate and become denatured, forming a coagulum.Transducer ENDOT55.5IndicationsThe UHS14 System is indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The System instruments can be used as an adjunct to or substitute for electro surgery, lasers, and steel scalpels.Contraindications The instruments are not indicated for incising bone. The instruments are not intended for contraceptive tubal occlusion.System ComponentsGeneratorThe generator supplies the hand piece with electrical energy and facilitates selection of power levels, system monitoring, and system diagnostics.Power is delivered by activating the foot switch or hand switching adaptor.Hand PieceThe hand piece contains an acoustic transducer that converts the electrical energy supplied by the generator to mechanical motion. The transducer is connected to an ultrasonic wave guide/amplifier which amplifies the motion produced by the transducer and relays it to the instrument.InstrumentThe mechanical motion from the hand piece advances to the instrument, transmitting ultrasonic energy which enables haemostatic cutting and/or coagulation of tissue.Power LevelsThe generator delivers two power levels: minimum (MIN) and maximum (MAX). The minimum power level may be adjusted by the user from Level 1 to 5. The maximum power level is always Level 5. With all instruments except the ball coagulator, use a higher generator power level for greater tissue cutting speed and a lower generator power level for greater coagulation. For the ball coagulator, higher generator power levels will provide greater coagulation. The amount of energy delivered to the tissue and resultant tissue effects are a function of many factors including the power level selected, instrument characteristics, grip force (when applicable), tissue tension, tissue type, pathology, and surgical technique.Appendix: Our Ultrasonic Scalpel UHS14 compared with J&J,Accessories compatibleNameUHS14J&J GEN300J&J GN11Input voltageAC90-240VAC90-240VAC90-240VOperating temperature10-30°10-30°10-30°Driver frequency55.5kHz55.5kHz55.5kHzScalpel vibration50-100um50-100um50-100umUltrasonic transducerHPT55.5S,HPT55.5BHP054,HPBLUEHP054,HPBLUEHP054,HPBLUEUltrasonic hand piece scalpelHPS36P,HPS23P,etcHPS36P,HPS23P,etc ACE36E,ACE23E,etcACE36E,ACE23E,etcHAR36,HAR23HAR36,HAR23HPS9B(FOCUS)HPS9B(FOCUS)PCS9(FOCUS)PCS9(FOCUS)PCS9(FOCUS)Use of the hand piece scalpelHit a hard object without damageHit a hard object will be damagedHit a hard object will be damagedCan closure 5mm VascularCan closure 5mm VascularCan closure 5mm VascularHemostatic cutting fastHemostatic cutting fastHemostatic cutting fastDisinfection of the hand piece scalpelSupport 134°C sterilizationNot support 134°C sterilizationNot support 134°C sterilizationReuseDisposable productsDisposable productsPedalFSW01FSW01--GeneratorSelf-testSelf-testSelf-testFault DisplayFault DisplayFault DisplayWorking VoiceWorking VoiceWorking VoiceSound FailureSound FailureSound FailureApplicable scopeFor laparoscopic surgeryFor open surgeryFor superficial surgeryFor laparoscopic surgeryFor open surgeryFor superficial surgeryFor laparoscopic surgeryFor open surgeryFor superficial surgeryNot ApplicableBone cutting and tubal closureBone cutting and tubal closureBone cutting and tubal closure
举报收藏 0
更多>本企业其它产品
Surgical Reusable Medical Endoscopy Trocar 30deg  2.7X175mm Arthroscope with Arthroscopy Sheath and Obturators  Blakesley Forcep 0deg 5X300mm Veterinary Laparoscope Thoracoscope with Trocar  Forceps HD 21.5" Endoscopy Surgical Monitor Gynaecology Parallel Laparoscope (8mm) Laparoscopy Forceps Rigid Endoscope with Different Size Urology Surgical Endoscope Resectoscope
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报