St-11 Dental Use Camera Obscura

 
 
单价 200.00 / Piece对比
询价 暂无
浏览 63
发货 Chinaanhuisuzhou
过期 长期有效
更新 2020-05-16 20:58
 
联系方式
加关注0

Suzhou Ronty Technology Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: St-11 Dental Use Camera Obscura Model NO.: ST-11 Power Source: Electricity Style: Luxury Application: Adult, Child Certification: ISO9001, CE Condition: New Trademark: Ronty Transport Package: Standard Export Specification: plastic and metal Origin: China Product Description Installation Notes1. The pocket darkroom placed on a fixed desktop.2. Open the lid on the portable darkroom.3. The developer posted (A), stop bath (B), the fixing solution (C), water (D) four cups from left to right into the four holes in the pocket darkroom site.4. Open A, B, C three cups lid and tearing the sealing film back into the original position, D cup water.5. The film holder hanging on the wire pocket darkroom.6. Replace the lid, you can use a portable darkroom.Instructions for use1. Measured with a thermometer developer (A) temperature.2. The dental film radiography after extending into the pocket darkroom two eyes, torn sheet bags remove the film, the film is clamped on any corner of the film holder.3. Referring to developer (A) listed in Table developing time (or press a personal washing time developing empirical observation results, determine development time).4. The film holder with the film quickly immersed in developing solution (A), and stir for 10 seconds, hanging cup quiet place for 2-5 minutes.Experience tells: When should a high temperature once every minute to observe the effect of development, to prevent over-black; when the low temperature once every 2 minutes to observe the effect of development. In short, we should achieve a satisfactory image until the desired treatment.5. After development, the film should be immediately placed in the film holder with stop bath (B), and stir for 10 seconds floating contact (Note: At this time the clip can not be returned to the developer).6. Then the film holder with the film into the fixing solution (C), stir for 10 seconds, hanging cup quiet place 2-4 minutes to complete the fixing film subject.7. Then the film holder with the film into the water (D) cup rinsed for 10 minutes. (If at this anxious to see the effect on the film viewer point of view on the wet sheet).8. Finally, the film in a clean place to hang dry or drying, archive.Precautions1. As self-made or purchased liquid other units, the adjustment should be on the table parameters to ensure image quality.2. To avoid damage or fingerprints appear on the radiograph, the operation need to be careful.3. A film thrown developer (A), should be immediately removed to prevent a developed black.4. When not covered with lid, to extend the use of time.5. To ensure high quality images, usually 15 days or 150 rinse after dental films, Xu new ones added. Cup after tearing the film valid for 30 days.6. A, B, C cups liquid splashed in the eyes, immediately wash with water.7. Pocket darkroom cover photoconductive material is expensive, pay attention to protection, to prevent rupture!
举报收藏 0
更多>本企业其它产品
Mt730 Slit Lamp Microscope Image Processing System RM800 Operation Microscope for Micro-Operation in Ear-Nose-Throat  Dental  Ophthalmology  Gynecology F-17-2 Movable Full-Fowler Hospital Bed with ABS Head/Foot Board (Central Locking) Rt-400A 7 "LCD Display Maternal & Fetal Monitor Rt-400L 12.1-Inch Color TFT with High-Resolution Maternal & Fetal Monitor RT-600C 7 Inch TFT True Color LCD Display  Prostate Therapy Instrument Mt-300S Baby Incubator with Microprocessor Based Servo Controlled Temperature System
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报