Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW)

 
 
单价 57.00 / Piece对比
销量 暂无
浏览 54
发货 Chinafujianningde
库存 3200Piece
过期 长期有效
更新 2020-08-03 15:48
 
联系方式
加关注0

Fuan Tongbo Electrical Machinery Co., Ltd.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW) Model NO.: TBS Brand: Tongbo Certification: ISO9001, CCC Starting Mode: Variable Frequency Starting Number of Poles: 2, 4, 6, 8 Casing Protection: Closed Type Rotor Structure: Squirrel-Cage Species: Tbs Number of Stator: Three-Phase Operating Speed: Constant Speed Application: Industrial Protection Class: IP21 Insulation Class: H Trademark: tongbo Transport Package: Carton/Wooden Case/Wooden Crate Origin: Fujian, China HS Code: 8501520000 Product Description Electric Character:EXCITATION SYSTEM:AVR: SX440, SX460, MX321, MX341The main stator supplies power to the exciter stator via the AVR. The exciter rotor output is provided to the main rotor by a three-phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges ecused by short circuit or lost Synchronization. Voltage regulation of SX440 AVR with three phase induction detecting module< ±0.5 %.MX321 and MX341 suitable for the generator with permanent magnetic generator (PMG).Electric FeaturesInsulation And Varnish:The insulation system is class H.All wound components are impregnated with materials and processes designed specifically ensure the generator running in dreadful conditions. The special developed resin materials meet rotating components.Windings and Electrical Performance:All generator stators are wound to 2/3 pitch, This eliminates triple(3rd,9th,15th…)harmonics on the voltage waveform and is an optimum designed for UPS equipment of non linear loads. The 2/3 pitch design avoids excessive neutral currents result from higher winding pitches. A fully consecutive damper winding reduces oscillations during paralleling. The 2/3 pitch windings and carefully pole and tooth ensures very low waveform distortion.Terminals And Terminal Box:Standard generators are 3-phase,and you can reconnect 12 ends of the terminals, which are mounted on a terminal block at the non-drive end of the generator. A sheet steel terminal box within AVR is provided with enough place for the customers'wiring. It has removable panels for easy access.Telephone Influence Factor:THF(BS EN60034-1)<2%THF(NEMA MG1-22)<50 Mechanic Features:SHAFT AND KEYAll generator rotors are dynamically balanced to better than minimum vibration of BS6861: part1 grade 2.5 double bearings generators are banlanced with a half key.ENGINE ADAPTOR AND COUPLINGAll generators are designed two kinds of construction. The adaptor and the drive plate is consonant with SAE standard.LEVELS Of PROTECTIonAll generators are IP2 and IP23 and IP44 can be optional for aircool protected generator. but rated power will decrease 5~10%.The Definition Of The Product Model:Option And AccessoryWindings temp protect thermistor and relayPMGMX321 or MX341Transformer for droop during parallelingTechnical dateModelRated Output(KW)Rated Capacity(KVA)Rated Vottage(V)Rated Current(A)Power Factor(CosфRated Speed(r.p.m)Rated Frequency(Hz)Gro$$ Weight(Kg)TBS164A6.58.140012.30.81500/180050/6095TBS164B8.81140015.80.81500/180050/60102TBS164C10.813.540019.50.81500/180050/60110TBS164012.816400230.81500/180050/60116TBS184E1822.540032.50.81500/180050/60141TBS184F2227.540039.70.81500/180050/60164TBS184G2S31.340045.10.81500/180050/60180TBS184H3037.540054.10.81500/180050/60230TBS184J324040057.70.81500/180050/60240TBS224C3442.540061.40.81500/180050/60225TBS224D405040072.20.81500/180050/60270TBS224E486040086.60.81500/180050/60290TBS224F58725400104.60.81500/180050/60330TBS224G6885400122.70.81500/180050/60370TBS274C80100400144.30.81500/180050/60435TBS274D91114400173.20.81500/180050/60460TB5274E1121404002020.81500/180050/60510TBS274F128160400225.50.81500/180050/60550TBS274G140175400259.80.81500/180050/60550TBS274H160200400288.70.81500/180050/60650TBS314C200250400360.80.81500/180050/60910TBS314D2362954004330.81500/180050/60975TBS314E2603254004690.81500/180050/601055TBS314F304380400548.50.81500/180050/601183TBS354C360450400656.80.81500/180050/601350TBS354D400500400721.70.81500/180050/601450TBS3S4E480600400880.50.81500/180050/601598TBS3S4F536670400967.10.81500/180050/601753REMARKAll the rated are on basis of environment temperature 40#C, altitude not exceeding 1000m.Different temperature offers different standby power, the define of standby power is related to the standard of ISO8528-3.All the rotors are 4 poles, as to other pole generator, please contact the manufacturer.Generators in other voltage range depend on costumers request
举报收藏 0
更多>本企业其它产品
40kw 55kVA Weichai Original European Technology Diesel Generator Sets 180kw 200kw 250kw 300kw Weichai Yz Series Diesel Marine Generator Sets Y Series Three-Phase Asynchronous Electric/Electrical AC Motor 50kw Weichai Marine Diesel Generator Set with Engine Wp4CD66e200 30kw Chinese Lovol Diesel Generator Set with 1003tg Engine 80kw/100kVA Three Phase Brushless AC Alternator Generator Tbs274c Tbyl Series Three-Phase Asynchronous Electric/Electrical AC Motor
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报