Laboratory and Medical Equipment Tabletop UV-Visible Spectrophotometer Price

 
 
单价 1.00 / Piece对比
销量 暂无
浏览 51
发货 Chinahenanzhengzhou
库存 2000Piece
过期 长期有效
更新 2020-05-06 18:20
 
联系方式
加关注0

Zhengzhou Laboao Instrument Equipment Co., Ltd.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Laboratory and Medical Equipment Tabletop UV-Visible Spectrophotometer Price Model NO.: LU-T8, LU-T9, LU-T1810 Customized: Customized Certification: ISO9001, CE Light Number: Polychromator Dispersive Element: Grating Spectrometer Wavelengths: UV Spectrometer Principle: New Spectrometer Advantage: High Resolution Detection Method: Spectrophotometer Warranty: 1 Year Application: Laboratory Apparatus Wavelength Range: 190-1100nm Spectral Bandwidth: 1.8nm Test Mode: Absorbance, Transmittance, Reflectivity, Energy Light Source: imported Tungsten Lamp and Xenon Lamp Display: Mobile Operation 10.1inch Capacitive Touch Screen Data Output: USB1.1 Email, U Disk Data Output Format: Csv, Pdf RAM: 32GB(up to 256GB) Power Supply: AC90~250V/ 50~60Hz Dimension (L*W*H) mm: 650*510*210 Weight: 29kg Product Name: Spectrophotometer Optical System: Czerny-Turner Double Detector Proportional Detecti Luminosity Range: 0~200%;T, -4~4A, 0~9999c(0-9999f) Noise: 0% Line Noise;0.08%;100 Line Noise: 0.15% Trademark: LABOAO Transport Package: Wooden Box Origin: China HS Code: 9027300000 Product Description Tabletop UV-Visible spectrophotometer price for lab1. Double beam UV-VIS Spectrophotometer series:LABOAO is proud to introduce the T8 series of dual-beam UV-Vis spectrophotometers based on the Android system. The series uses advanced mobile touch screen technology and has two models of fixed bandwidth and variable bandwidth.1. Fully sealed optical system design and integrated aerospace grade aluminum optical mounting platform for outstanding optical performance and permanent optical imaging; high quality optics and fully imported xenon and tungsten lamps for long-term stability and reliability.2. Leading ARM chip control and data processing; with 10.1 inch color touch screen display and user-friendly navigation menu design, convenient map display and data viewing; Bluetooth technology application, allowing the display to be moved on the hand, completely rid of the connection Binding; 32G large-capacity memory, can store massive test data; U disk data export, Wifi printing, mail sending and other data output methods.UV-Visible spectrophotometer withremovable LCD touch screen(LU-T8 and LU-T9 Series)Feature1. High stable: Czerny-Turner dual beam optical system, drift is less than 0.0008 Abs.2. High precision: Micrometer-class precision lead screw drive grating ensures wavelength accuracy <0.3nm; transmittance accuracy <0.3%; can reaches the Class I level.3.10.1 inch LCD touch screen, movable4. Android Android navigation menu operating system;5. The display graphic is transmitted by Bluetooth;6. With inernal specific program;7. 32G large capacity memory; USB, Email, USB flash drive and WIFI print data output.8. imported deuterium lamp and tungsten lamp;Function:1. Photometric measurement2. Quantitative measurement3. Qualitative measurement5. DNA/protein measurement6. Multi-wavelength measurement7. Affiliated functionsDeuterium lamp, tungsten lamp lighting cumulative time, xenon lamp, tungsten lamp independent off and on, ultraviolet and visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength auto-calibration, Wifi function, mailbox function.8. Software package functionQuantitative measurement, qualitative measurement, time measurement, DNA protein measurement, multi-wavelength measurement, 3D graphic analysis, map overlay analysis, etc.SpecificationDouble beamspectrophotometer(LU-T1810Series) DescriptionSpectrophotometry is often used in measurements of enzyme activities, determinations of protein concentrations, determinations of enzymatic kinetic constants, and measurements of ligand binding reactions. The use of spectrophotometers spans various scientific fields, such as physics, materials science, chemistry, biochemistry,Chemical Engineering, and molecular biology.Feature1. High stability: Czerny-Turner type dual beam optical system reduces chromatic aberration and ensures long-term data stability2. High precision: using a micrometer-scale precision lead screw to drive the grating to ensure wavelength accuracy <±0.3nm; transmittance accuracy is ±0.3%T, accuracy reaches Class I level3. Easy to use: 5.7-inch large-screen LCD display, map, curve at a glance, simple and convenient operation, quantitative, qualitative, dynamic, DNA / RNA, multi-wavelength analysis and other special test procedures4. Long service life: original imported xenon lamp, tungsten lamp, ensuring long life of 2 years, receiver life of up to 20 years5. A variety of accessories: automatic sampler, micro cell holder, integrated ball diffuse reflection, 5 ° specular reflection and other accessories, to meet special requirementsFunction:1. Photometric measurement: It is convenient to measure the absorbance and transmittance of the sample at the specified wavelength. The fixed-point test can test up to 10 wavelengths at the same time.2. Quantitative measurement: automatic establishment of standard curve, first-order / first-order zero-crossing, second-order, third-order curve simulation 3. Qualitative measurement: scanning speed 3500nm / min, map processing methods, including, scaling, smoothing, filtering, peak Valley detection, etc.4. Kinetic measurement: calculation of enzyme kinetic reaction rate, scaling, smoothing, filtering, peak-to-valley detection, derivation, etc.5. DNA/RNA, protein testing function, automatic calculation of sample ratio and concentration.SpecificationModelLU-T1810D, LU-T1810DPCLU-T1810DA, LU-T1810DAPCLU-T1810DS, LU-1810DSPCOptical systemCT type double beam optical system, 1200 strip / mm holographic grating splitting focal length 280nmWavelength range190-1100nmSpectral bandwidth1.8nm1nm0.5,1,2,4,5nm adjustableWavelength accuracy±0.3nmWavelength repeatability±0.1nmTransmittance accuracy±0.3%T;±0.002Abs(0-0.5Abs); ±0.004Abs(0.5-1.0Abs)Transmittance repeatability±0.1%T;±0.001Abs(0-0.5Abs);±0.002Abs(0.5-1.0Abs)Stray light≤0.03%T, at 220nm and 360nmNoise±0.0004AbsDrift±0.0008Abs(500nm, after pre-heating)baseline flatness±0.0008Absbaseline dark noise0.05%TLuminosity range0~200%T/-4~4A/0~9999C(0-9999F)Light sourceimported tungsten lamp and deuterium lampScanning speedhigh/ medium/ low three speed adjustableDisplay320x240nm Graphic LCDData outputUSB interface, Centronics parallel port (optional HP, Epson compatible laser, inkjet printer and micro printer)Power supply90-250V/AC,50-60HZ2. UV-VIS SpectrophotometerSeriesUV-VIS Spectrophotometer with 5.1 inch LCD display screen (LU-T6 Series):Feature1. High stability: integrated structure design (8mm heat-treated aluminum alloy base) to ensure long-term reliability and stability of the instrument2. High precision: The micro-scale precision screw drive grating is used to ensure the wavelength accuracy <±0.5nm; the transmittance accuracy is ±0.3%T, and the accuracy reaches the class II level.3. Easy to use: 5.1-inch large-screen LCD display, map, curve at a glance, simple and convenient operation, quantitative, qualitative, dynamic, DNA / RNA, multi-wavelength analysis and other special test procedures4. Long service life: Original imported xenon lamp, tungsten lamp, ensuring long life of 2 years, receiver life of up to 20 years5. A variety of accessories: automatic suction, micro-pool rack, integral ball diffuse reflection, 5 ° specular reflection and other accessories, to meet special requirementsFunction:1. Photometric measurement: It is convenient to measure the absorbance, transmittance and fixed point test of the sample at the same time. It can test up to 10 wavelengths at the same time.2. Quantitative measurement: automatically establish standard curve, first-order / first-order zero-crossing, second-order, third-order curve fitting, single-wavelength correction, dual-wavelength correction, three-point method optional, standard curve can be stored and recalled3. Qualitative measurement: scanning speed 3500nm / min, map processing methods, including, scaling, smoothing, filtering, peak and valley detection, etc.4. Kinetic measurement: Enzyme kinetic reaction rate calculation, scaling, smoothing, filtering, peak-to-valley detection, derivation, etc.5. DNA/RNA, protein testing function, automatic calculation of sample ratio and concentrationSpecificationModelLU-T6 / LUT6PC LU-T6A/ LU-T6APCOptical systemSelf-aligned optical system, 1200 strips/mm holographic gratingWavelength range190-1100nmSpectral bandwidth4nm 2nmWavelength accuracy±0.5nmWavelength repeatability±0.2nmTransmittance accuracy±0.3%T, ±0.002Abs(0-0.5Abs),±0.004Abs(0.5-1.0Abs)Transmittance repeatability±0.1%T, ±0.001Abs(0-0.5Abs),±0.002Abs(0.5-1.0Abs)Stray light≤0.05%T at 220,340nmNoise±0.0015AbsDrift±0.0015A/H at 500nm, after prehetingbaseline flatness±0.0015Absbaseline dark noise0.1%TLuminosity range0-200%T,-4-4A,0-9999c(0-9999f)Light sourceimported deuterium lamp and tungsten lampsDisplay320x240 LCD displayScanning speedHigh, medium and low 3grade / Max. speed 4600nm/minLanguageChinese and English Automatic switchingData outputUSB interface, Centronics parallel port, (with built-in and external micro printer)Power supply90-250V/AC 50-60HZSpectrophotometer withTouch screen and keyboard( LU-T5Series):Feature1, easy to use-4.3-inch color touch screen technology and keyboard parallel input mode, easy to operate.-Navigation menu design, testing is simpler and easier to use.-Built-in photometric, quantitative, qualitative, time measurement, DNA protein measurement, multi-wavelength measurement, GLP-specific procedures;-U disk data export, USB connection computer2, a variety of accessories are optional5-10cm optical path cuvette holder, automatic sample holder, peristaltic pump autosampler, water thermostatic sample holder, Peltier thermostat sample holder and other accessoriesFunction:1. Photometric measurement: The absorbance or transmittance of the sample can be determined by selecting the single-point test wavelength and test method you need in the range of 190-1100 nm. The concentration of the sample can also be read directly by entering the standard concentration or concentration factor.2. Quantitative measurement: Measure the sample solution of unknown concentration by curve of known parameter factor or automatically establish standard solution curve; have first-order, first-order zero-crossing, second-order, third-order curve fitting, and single-wavelength correction, double Absorption correction such as wavelength, three-point method is optional; standard curve can be stored and recalled;3. Qualitative measurement: Set a wavelength range, scan interval, and then measure the absorbance, transmittance, reflectance, and energy of the solid or liquid sample at intervals. It is also possible to scale, smooth, filter, detect valleys, save, print, etc. the already measured maps;4. Time measurement: Time measurement is also called dynamic measurement. The sample is scanned according to the time range of absorbance or transmittance according to the set wavelength point. The absorbance can also be converted into concentration or reaction rate by input concentration factor.Enzyme kinetic reaction rate calculation. A variety of map processing methods such as scaling, smoothing, filtering, peak-to-valley detection, and derivation are available for you to choose from;5. Measurement of DNA/protein: The absorbance is measured at several points of 260 nm/280 nm/230 nm/320 nm, and the concentration and ratio of DNA and protein are obtained according to the calculation formula.6. Multi-wavelength measurement: It is possible to set up to 30 wavelength points and measure the absorbance or transmittance of the sample solution.7. Auxiliary functions: deuterium lamp, tungsten lamp lighting cumulative time, xenon lamp, tungsten lamp independent off and on, ultraviolet and visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength automatic calibration.SpecificationModel LU-T5/T5PC LU-T5A/T5APC Optical system Self-aligned; 1200 / mm imported holographic grating Wavelength range 190~1100nm Spectral bandwidth 4nm 2nm Wavelength accuracy ±0.8nm Wavelength repeatability ±0.2nm Transmittance accuracy ±0.5%T Transmittance repeatability ±0.2%T Stray light ≤0.1%T Noise 0% Line noise:0.1%; 100 Line noise:0.2% Drift ±0.002Abs(Preheating for more than 1hour) baseline flatness ±0.002Abs(Preheating for more than 1hour) baseline dark noise 0.2%T Luminosity range 0~200℅T,-0.301~3A,0~9999C(0-9999F) Test mode Absorbance, transmittance, energy Light source tungsten lamp and deuterium lamp Display 4.3inch 56K touch screen Software package Optional Data output USB U disk Power supply AC90~250V/ 50~60Hz Dimension (L×W×H) mm 460×310×180 Weight 12kg UV-VIS Spectrophotometer (LU-T3Series):Feature1. High stability: Optimize the structure of the optical system and integrated aluminum alloy base structure, to ensure long-term stability and reliability of the instrument2. Intelligent degree is high: Dual CPU embedded system hardware design of super reliable,128*64 LCD display, rich instruction, without reading the manual, is simple and convenient to use; custom wavelength correction and automatic wavelength calibration function, replacing the artificial adjustment link; light source using time automatic accumulation, convenient view to understand, light source switch menu can be in the instrument does not use circumstances to choose to close, prolong the equipment service life.3. Menu functions: Photometric measurement model, quantitative analysis, qualitative analysis, dynamic test, multi wavelength test.4. Data processing is convenient: can store up to 1000 groups of experimental data, optional built-in and external printer output, or optional NANBEI spectrum analysis software package and connected to the computer, to achieve more data processing and analysis functions.Function:1. Photometric measurement: to facilitate the measurement of the absorbance, transmittance, concentration of the sample at a specified wavelength.2. Automatic quantitative measurement: to establish the standard curve, a first-order, zero order / two order and three order curve fitting, a variety of optional quantitative analysis standard curve method can store and call.3. Qualitative measurement: do more to support the continuous recording of 100 data points, automatically find the maximum absorption peak wavelength position4. Kinetics measurement: enzymatic kinetic reaction rate calculation5. Multi wavelength measurement: data measurement with up to 10 wavelength pointsSpecification:ModelLU-T3LU-T3AOptical SystemSingle, Grating 1200 line/mmWavelength Range190~1100nmSpectral Bandwidth4nm2nmWavelength Accuracy±1nmWavelength Repeatability±0.2nmPhotometric Accuracy±0.5%T;±0.002Abs(0~0.5Abs);±0.004(0.5-1.0Abs);Photometric Repeatability±0.2%T;±0.001Abs(0~0.5Abs);±0.002(0.5-1.0Abs);Stray Light≤0.05%T, @360nm≤0.05%T, @220nm/360nmNoise Level±0.0015AbsStability±0.0015A/h@500nmPhotometric Range0~200℅T,-0.301~3A,0~9999C(0-9999F)Light SourceTungsten Lamp (Pre-aligned)Display128×64 Dots Array Graphic LCDSystem LanguageEnglishOutputUSB1.1 Connecting to computer&Parallel port for printerPower RequirementAC90~250V/ 50~60HzDimensions(L×W×H)550×400×220Weight13kg
举报收藏 0
更多>本企业其它产品
Egg Powder Making Machine Small Laboratory Spray Dryer Equipment for Milk Coffee Tea Laboratory Medical Analysis Equipment Tabletop UV-Vis Visible Spectrophotometer Price Egg Powder Making Machine Small Laboratory Spray Dryer for Milk Coffee Tea High Precision 0.001mm Resolution Thickness Testing Gauge Digital Ultrasonic Flaw Detectors Equipment in Physics Ultrasonic Washer 25kHz  33kHz  40kHz and 59kHz Sweep Frequency Cleaning Machine for Sale Cheap Ultrasonic Sonicator with LCD Display Used Milk Homogenizer Double Tower Double Distilled Water Distiller Machine
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报