Laboratory Vacuum Glove Box with H2O & O2 Purification System

 
 
单价 23.00 / Piece对比
销量 暂无
浏览 165
发货 Chinahenanzhengzhou
库存 500Piece
过期 长期有效
更新 2020-04-23 05:29
 
联系方式
加关注0

Zhengzhou CY Scientific Instrument Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Laboratory Vacuum Glove Box with H2O & O2 Purification System Model NO.: CY-VGB-6 Power Source: AC220V Shipping Weight: 640 Kg (1400 Lbs) Trademark: CYKY Transport Package: Wooden Case Specification: 86" L x 45" W x 91" H Origin: Zhengzhou, China Product Description Descriptions:CY-VGB-6is a stainless steel glove box with thehinged type of front door designed for much easy loading and unloading device into the glove-box. The purification cylinder is made ofCopper Catalystand Lindy Molecular Sievein order to achieve a low water and oxygen concentration of lower than 1 ppm, such that experiments can be conducted in a ultra-clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, and system data log recording. CY-VGB-6 is widely used in preparing nanomaterials, Li-ion battery materials,catalysts, and metallorganics.NEW!! The VGB-6 glove box system has been upgraded with the hinged type of front window with the main chamber since Dec. 2015. Such feature enables easy transportation for larger size equipment into the glove box. Technical Parameters:Working Voltage110 or 220 VAC switchable, 50/60 Hz, single phaseMax power: 1.5 kWGlove Box ChamberCase Material: Stainless steel 304 with 3 mm thicknessChamber dimension:1200 mm L x740 mm W x900 mm HOpenable front window panel (tempered glass, 8 mm thick)Chamber ConditionWater concentration: <1 ppm (20 °C, 1 atm)Oxygen concentration:<1 ppm (20°C, 1 atm)Leak Rate<0.05 vol% / hr (depending on oxygen concentration inside the glove box)Airlock ChamberAntechamber dimension:360 mm Dia. x600 mmLSmall chamber dimension (for tools):150 mm Dia. x220 mm LWorking GasOperating gas: Inert gas such as N2, Ar, HeRegenerating gas:For regenerating both oxygen and H2O remover, use mixture of H2 (5-10%) and operating gasGas Purification SystemAutomated regeneration processAutomated water and oxygen removalPurification cylinder: made of BASF R3-11 Copper Catalystand Lindy Molecular SievePipeline:304 stainless steel,KF40 and KF25 portsports & fittingsTotal seven KF40 ports on the back of the glove boxFilter SystemInlet and outlet filtercan eliminate particle size > 0.3μmPressure Control SystemAutomatic pressure control by PLC for the Glove Box ChamberPressure range: +/- 12 mbarManual pressure control is allowed via a foot pedalPurging SystemAutomatic purging system allows easy operating and reduces gas consumptionControl SystemSiemens PLC control system with6" touchscreen displayWater concentration: 0 - 1000 ppm with an accuracy of 0.1 ppmOxygen concentration:0 - 1000 ppm with an accuracy of 0.1 ppmPressure: -25 to 25 mbar with an accuracy of 0.01 mbarAutomatic system data loggingPump240 L/m heavy duty double stage rotary vane pumpfor faster gas exhaustVacuum rate: 240 L/m (8.5cfm)GlovesA pair of 9 3/4" butyl glove is included for immediate useLightingBuilt-influorescent lampDimensionProduct Dimension: 2000 mm L x1000 mm W x1880 mm H (79" x 40" x 74")Shipping Dimension86" L x 45" W x 91" HShipping Weight640 kg (1400 lbs)complianceUL certifiedglove box is available upon request with extra cost, please choose model# LAB2000 in the option bar.WarrantyOne year limited warranty with lifetime supportRusting and damage due toimproper storage condition or maintenance are not covered by warrantyGloves are consumable items and are NOTcovered by warrantyThe oxygen sensor is a consumable component NOTcovered by warranty. Please use the videos below for properly 1) Replacing a worn unit and 2) Storing the sensor to ensure maximum longevity when not usedApplication Notes & WarningsThe interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles.The O2 removing rate is largely dependent on the type of purging gas used. For faster chamber purging process, Nitrogen is preferred over Argon due to its lighter massRegularly perform regeneration to maintain the optimum purification efficiency.O2 sensor isconsumableand its expectedlife-spanis around one year. We supplyreplacement O2 sensor.The use of corrosive gases is prohibited as they will damage the water and oxygen sensors!Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid vapour may condense and corrode the steel chamber and purification pipeline.We can connect various tube furnace with the glove box for processing air sensitive materials Pictures oflaboratory VacuumGlove Box Structure of laboratory vacuumGlove box:Laboratory vacuum glove box with furnace:Pump picture:Contact Information:
举报收藏 0
更多>本企业其它产品
Factory Price Desktop Rotary Magnetron Sputtering Coating Machine for Metal Films Laboratory Dual-Head Vacuum Magnetron Sputtering Machine for Thin Film Coating Three Two-Inch Target Heads RF Magnetron Sputtering Coating Machine for Lab Stainless Steel Chamber Vacuum Thermal Evaporation Deposition Coating Machine Evaporation Plasma Sputter Coating System for Non-Conductor Material Test Electrode Dual-Target RF Magnetron Sputtering Vacuum PVD Coating Machine High Vacuum High Temperature CVD Coating Machine for Lab Long Operating Life High Power Cathode Magnetron Sputtering Coating Machine
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报