Interrupteur aé Rien à Commande Manuelle Rocking Disconnectors

 
 
单价 11.00 / Piece对比
销量 暂无
浏览 224
发货 Chinahubeisuizhou
库存 7000Piece
过期 长期有效
更新 2020-08-18 10:56
 
联系方式
加关注0

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Interrupteur aé Rien à Commande Manuelle Rocking Disconnectors Model NO.: GW4-33 2000 Trademark: OEI Power Transport Package: Wooden Case Specification: IEC IEEE Origin: China Nanyang HS Code: 8535309000 Product Description Center Break Isolator and double Break IsolatorThese disconnectors are , no load switching deviceswhich physically isolate the lines. They are designed forhorizontal outdoor application and can also be designedfor vertical installation. For earthing and closing ofswitchyard portions of the installation, the earthingswitches are provided on disconnector. If required.The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing SwitchesIEC 60694:2002: Common Specifications for High Voltage Switchgear and ControlgearBS 729: Hot dip galvanized coating on iron and steel articlesIEC62271-102Isolator (Disconnector) - a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.SERVICE ConDITIONSThe isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.4.2. DESIGN AND CONSTRUCTION4.2.1 The Isolator, Solid link shall be designed and constructed in accordance with IEC 129 and IEC 60694.4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on 'U' type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.4.2.7 The solid link shall be removable from the mounting by use of operating rod.4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor ofAluminium (ACSR)conductor of up to 18.2mm diameter.The rating of the complete isolator shall be as follows: -Rated voltage36 kVRated frequency50 HzRated lightning impulse withstand voltage200 kVRated power frequency withstand voltage, dry95 kVRated normal current400 AmpsRated short time withstand current for 3 sec, min.18.0 kAMinimum creepage distance of insulators900 mmSystem Voltages132kV1System:50 Hz, 3phase2Neutral Point EarthingSolidly EarthedEarthing Resistor3Nominal voltage of networks132kV4Highest system voltage as defined by IEC - 38145kV5Short circuit not less than [MVA] N/A6Short circuit and earth fault current, symmetrical r.m.s. value not less thanN/A7Thermal short circuit current, 1 second not less than31.5 kA8Dynamic Peak current not less than80 kA9Continuously rated currents of Isolating Switches:1 600 A10Isolation Voltage according to IEC - 7110 a- Switching Surge withstand voltage Phase to earth 275 kV- Longitudinal impulse component of combined test325 kV10 b- Lightning Impulse withstand voltage 1.2/50 micro-s To earth and between phases650kVpAcross the isolating distance of isolating switches750 kVp10 c- Test voltage at power frequency 1 minute, dry and wet (at sea level)To earth and between phases (r.m.s.)N/AAcross the isolating distance of isolating switchesN/A11For the design and erection of the conductors in the switchyard the following minimum distance shall be observed:11aPhasetoground [mm]1 500 11b- Phasetophase2 33011cBusbars phasetophase3 50011dHeight to live parts above ground5 50011eHeight to live parts above ground at service/transportation strips [mm]5 50011f- Lowest part of insulators above ground [mm]3 50012Maximum temperature rise of conductorsabove ambient temperature (45oC)40oC13Maximum wind pressure on conductors and cylindrical objects430N/m214Maximum wind pressure on flat surfaces820N/m215Minimum nominal creepage distance as defined in IEC 815, Table II25 mm/kV
举报收藏 0
更多>本企业其它产品
10kv Cast Resin Dry Typehigh Voltage Power Electric Toroidal Transformer Gw9 -12/630 Series Hv Outdoor High Voltage Disconnect /Switch Isolator Outdoor Sf6 Gas Circuit Breaker 33kv Auto Recloser Circuit Breaker Disconnect Switch Isolator Single-Pole 600A Lightning Arrester  Surge Arrester  Pararrayos  Parafoudre 3-132kv  10ka Meter Box Isoladores De Porcelana P-33y Polymer Insulator
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报