ICU Ventilator with Ce Approved (AM-700B)

 
 
单价 面议对比
询价 暂无
浏览 223
发货 Chinajiangsunanjing
过期 长期有效
更新 2020-05-06 21:51
 
联系方式
加关注0

Nanjing AMIS Medical Technology Co., Ltd.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: ICU Ventilator with Ce Approved (AM-700B) Model NO.: AM-700B Type: Ventilator Size: 10.4'' Certification: CE, ISO13485 LCD Display: With LCD Display Source: Oxygen Anesthesia: Semi Open Suction Type of Operating Light: Not Kind: Surgical Group: All Trademark: AMISMED Transport Package: Carton Origin: China HS Code: 90192000 Product Description ICU Ventilator with CE approved (AM-700B) without/with Air CompressorProspective service and supportThe AM-700B II ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.ALL MACHINE UNIT HAS PASS THE CEThe automatic conversion for standby power while AC power outage, keep working not less than 1 hourTECHNIQUES SPECIFICATIonSPhysical specificationsDisplay10.4'' LCD DisplayMode:pneumatically powered and electrically controlled systemTrolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical Specifications:Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve<12.5 kPaRespiratory Rate1 ~ 99 bpmOxygen Concentration21% ~ 100% Maximum Minute ventilation≥18L / minmodes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPonTVentilator compliance≤30 Ml/kPaPEEP:0 ~ 1.0 kPaPtr:-10 ~ 10 hPaIMV frequency:1~20 bpmI/E Ratio:4:1~1:4, Has the inverse ratio ventilationTidal VolumeSetting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting pointPressure limit range:1.0~ 6.0kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm:≥ 18L/ MINPower Supply AlarmAc/dc power supply are after failing to send out alarm immediatelyAlarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature:10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement:100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be well grounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.StorageAmbient temperature:-15oC~ +50oCRelative humidity:no higher than 95 %Atmospheric pressure:86 kPa ~ 106 kPa.It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportationMoisture protection and rain protection to ensure that product is protected from natural damage.Safty & AlarmGas source pressureImmediate alarm; "high level alarm" indicator flickers raising an audible alarm.Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle.Ventilation Volume AlarmLower: 0~12L/Min; Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.STANDARD CONFIGURATIONSQTYNAME1 setMain unit1 setOxygen tube2 setSilicone Mask1 pcPower line4 pcsThreaded pipe2 pcsStandard Pipe1 setOxygen Reducer1 setHumidifier1 pcBattery2 setflow sensor2 pcsA leather bag ( Blue)1 setTools with the machine1 setUser Manual (English Version)
举报收藏 0
更多>本企业其它产品
Medical Hospital Lab Clinical Chemistry Analyzer Chemistry Analyzer Anethesia Dispopsables Central Venous Catheter Kit Biosafety Cabinet Biological Safety Cabinet Class II A2 Am-11231bbc86 Infant Radiant Warmer Infant Incubator (AM-100A) BMI Body Fat Analyzer and Height Measuring GS6.6 (Am-9000d) Monophasic & (Am-8000d) Biphasic Defibrillator Intergrated System Patient Monitor (AM-U7200) EEG (Routine EEG System & Ambulatory EEG System)
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报