High Voltage 33 Kv and Advanced Discharge Lightning Rod Static Copper Earthing Portable 11kv to 500

 
 
单价 10.00 / Piece对比
销量 暂无
浏览 183
发货 Chinatianjin
库存 10000Piece
过期 长期有效
更新 2020-08-18 17:21
 
联系方式
加关注0

XIN CHENG INDUSTRY MATERIAL CO., LTD.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: High Voltage 33 Kv and Advanced Discharge Lightning Rod Static Copper Earthing Portable 11kv to 500 Kv FRP Discharge Rod Model NO.: High Voltage 33 kv and advanced discharge lightnin Brand: Xincheng Size: Customized Certification: CCC, ISO9001, ROHS Symbol: Xincheng Material: Galvanized Copper Earthing Method: Direct Earthig / Indirect Earthing Application: High Voltage Transmission Line Working Voltage: High Voltage Usage: Working Earthing, Earthing System, Lightning Protection Earthing, Protection Earthin Product Name: Discharge Rod Type: Extension or Telescopic/ Connection Type Function: Discharge Material of Rod: Epoxy Resin Rod, Copper Cross-Section Area of Cable: 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2 Material of Clamp: Aluminum or Copper as Request. Discharge Rod Extension Size: 2- 5 Sections or as Request Stretch Length: 900mm-- 6000mm or as Request Voltage Grade: 3kv . 6-10kv . 10kv . 30kv . 35 Kv . 110kv . 140kv Impedance: Different as Different Type Product. Warranty: 3 Years Color: Red, Green, Yellow or Customized. OEM: Available. Certificate: ISO9001:2008, IEC60947and IEC60269standarded Discharging Time: Tens of Seconds Trademark: XINCHENG Transport Package: Pallet Specification: PIECE Origin: China Product Description Quick DetailsPlace of Origin: China Brand Name: XINCHENGProduct name: discharge rod Type: Extension or telescopic/ Connection typeFunction: discharge Material of rod: Epoxy resin rodKeyword: High Voltage Discharge Rod Material of cable: copperCross-section area of cable: 16mm2,25mm2,35mm2,50mm2,70mm2,95mm2,120mm2Material of clamp: aluminum or copper as request.Discharge rod extension size: 2- 5sections or as request Stretch length:900mm-- 6000mmor as requestVoltage grade: 3kv .6-10kv .10kv .30kv .35 kv .110kv .140kv. 220kv .330kv .500kvVoltage level: different level due to requirements External diameter:25-40mmas for different typeCondition: Underground Installation: vertical type, horizontalImpedance: 6.6-25MΩ, different as different type product. Strength: >=600N/mm2Color: Red, Green, yellow or Customized. Warranty: 3YearsOEM: available. other voltage of the discharge rod can be customized, the size and impedance of different voltage levels of discharge rod are different.Certificate: ISO9001:2008 ,IEC60947and IEC60269standarded. HS Code: 9031809090Discharging time: tens of secondsProduct DescriptionInsulated Fiberglass Hot Stick Cutout Fuse Surge Arrester Hv Telescopic Insulation Operating RodNon Linear Carbon Discharge Resistor Type Discharge Rods are used to discharge dead system having limited fault levels and also to discharge the static &induced charges in the dead system or equipment, particularly in transmission lines, cables, transformers, reactors, large bus bar systems, switch-gears etc. The earthing lead is made up of special highly flexible braided copper cable with transparent sheath. Copper Hook and copper rod &Earth End Clamp of special alloy are provided.Composition:discharge rod +single-phase ground wire +grounding clamp.Uses:The high voltage discharge rod can be usde for on-site high voltage test, especially in DC withstand voltage test, it should carry out aground discharge for the accumulated charge on tested objects to ensure personal safety.Portable telescopic rod model is easy to use in the outdoor high voltage test, especially in DC voltage test, to test the charge accumulation, to discharge, to ensure personal safety using the discharge rod discharge, is to ensure that the necessary for each test of the personal safety of the weapon. Portable telescopic rod is easy to carry, convenient, flexible, has the advantages of small volume, light weight, safe and reliable, is asafe tool of high voltage staff lack.The use of methods1. pull out the telescopic part of the portable telescopic discharge rod2. the prepared grounding wire plug is inserted into the socket of the head end of the discharge rod, and the other end of the ground wire is connected with the earth, and the grounding is reliable3. discharge should be completed after the test, the DC generator control box booster knob back to zero, at this time can observe the control box of the voltmeter voltage drop to 15KV ~20KV or so, can dischargeThe 4. discharge should be the first to use the metal pointed front rod, go slowly on into disconnected power supply test samples. At this time the discharge rod release electricity is after discharge resistance of discharge. Then the discharge rod on the hook to hook the sample, second electricity.Matters needing attention1. of the sample capacitor discharge, should be in after the test, disconnect the power after the test, you should wait for aperiod of time, the charge on the cylinder and the sample times by itself on the self discharge. This can be observed on the control box of the voltage meter voltage the gradual decline in the fall, when voltage meter down to alower voltage, usually in 5Kv ~15Kv, available discharge rod to gradually move to the sample nearby. First through the air gap free discharge, then you can hear ahissing sound, when no sound, with atip to touch the discharge rod test, finally test direct grounding discharge.The magnitude of the accumulated charge of the 2. large capacitance specimens is proportional to the size of the sample capacitor and the applied voltage, and is proportional to the time3. after afew kilometers above the high voltage cable test, the discharge time is generally very long, and need to repeatedly discharge. Resistance capacity is large, need to order alarge capacity of the discharge rod4. is strictly prohibited without open test power to discharge the sample with the discharge rod.5. strictly prohibit the use of foot and heavy extrusion rod, bending, breaking the discharge rod is strictly prohibited6. prohibit the discharge rod damp, affect the insulation strength, should be placed in the dry placeHigh voltage ground wire classification(1) high-voltage ground wire in accordance with the use of the environment can be divided into: indoor busbar grounding line and outdoor line-type ground wire .(2) high-voltage ground wire in accordance with the voltage level can be divided into: 10KV ground wire, 35KV high voltage ground wire, 110KV grounding line, 220KV high-voltage ground wire, 500KV high-voltage ground wire(3)According to the connection mode of FRP insulating rod, it can be divided into Connection straight type and Telescopic typeConnection straight type Earthing Rod(10 to 500 KV)Voltage gradeSectionRod Length mmDiameter of the rod in hand mmcable mmgrounding clamp10KV213003516/25Single /double hole35KV217003516/25Single /double hole110KV224003516/25Single /double hole220KV334003525/35Single /double hole500KV4-560004035/50Single /double holeRemark: the cable length customized,Clamp is aluminum or copper as requestTelescopic type Earthing Rod (10 to 500 KV)Voltage SystemSectionRod shrinkage Length MMRod Stretch Length MMImpedanceMΩgrounding clamp6KV265010006.6Single /double hole10KV265010206.6Single /double hole35KV365015008.8Single /double hole110KV3810200016Single /double hole220KV31150300018Single /double hole500KV51250600025Single /double holeRemark: the cable length customized. The diameter of the top rod is 20mmResistance requirements: Model 16mm225mm235mm250mm270mm295mm2120mm2Resistance1.24mΩ0.79mΩ0.56mΩ0.40mΩ0.28mΩ0.21mΩ0.16mΩFeatures1.FRP Rods can be used for KV test level2.Special pultruded fiber glass Rods are used for proper insulation and long life3.cable Dismentable, Additional lengths are also available4.customized cable length Earthing lead with proper clamps5.Non-Inductive Resistor to drain the high voltage smoothly which enables the pitting on the test piece and corona discharge6.Waterproof bag is provided7.Very light in weight and workable in all weather conditions .8. No need any working power supply, small volume, light weight for portable.9.with special HV resistor, resistance is up to 1500MΩ,safe and reliable.10.Corrosion and abrasion resistant11.Dimensionally precise12.Highly effectiveOur ServicesFrom the date of purchase our instrument, the warranty time is 36 months. This is the piriod of free repair replacement, lifetime supply of maintenance and technical services. If the instrument has been found anomalies or malfunctions please contact us to arrange the most convenient treatment options.FAQHow long is your products warranty ?A: The warranty period of our products is 36 months.2 How about inspection?A: We have the whole inspection system from raw material to end products include temperature test,strength test and so on.3 What do you have for certificate?A: Our products are passed through IEC60947and IEC60269standarded.4 What is payment terms?A: T.T, Western Union and L/C is acceptable.5 What is the service offered by company?A: We have the professional enginer team which can design and develop the mold to arrive different customer nequirement.We also have the sales team to offer good service from pre-sale to after-sale.For other related products, please contact us:1) Fiberglass Earthing Rod series products;2) Compact substation insulation operation rod;3) Extension high-voltage operation rod (brake pull-off rod);4) Ultraportable Height Finder Rod(range finder ruler)5) High-pressured electroscope series products;6) High voltage signal indicator series products;7) Security earth wire series products;Packaging &DeliveryPackaging Details: Suitable packing for export: Cartons+ Wooden cases+ Pallets+ Wrapping FilmPort: Qingdao/Tianjin/Shanghai/ShenzhenPlease Contact UsMiss: lydiaMob: 86-13752439076 Fax: 86-22-60863016 http://www.chinainsulatingmaterial.com
举报收藏 0
更多>本企业其它产品
1050/1060/1350 Aluminum Busbar for Transformers Highly Flexible Copper Foil Soft Connectors for Electrical Transformers Parts Series Specification Soft Electrical Busbar Connectors Fr4 Rectangular Nuts (yellow) for Transformer Fixing/G10 Nuts/ G10 Bolts Bkl Tube for Transformer/Distribution Transformer Insulation Tube/Bakelite Tube Epoxy Diamond Dotted Insulation Paper (DDP paper) /Insulation Paper/Heat Insulation Material  Even 1 Customized 15mm to 1650mm Mylar 6021 Milky White Pet Polyester Film Electrical Insulation Material I DMD Film for Transformer Winding
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报