High Quality Moulded Case Earth Leakage Circuit Breaker

 
 
单价 面议对比
询价 暂无
浏览 81
发货 Chinazhejiangwenzhou
库存 100
过期 长期有效
更新 2020-08-18 05:17
 
联系方式
加关注0

Yueqing Long Road Electric Co., Ltd.

企业会员第6年
资料未认证
保证金未缴纳
详细说明
Product Name: High Quality Moulded Case Earth Leakage Circuit Breaker Model NO.: MM1L Certification: ISO9001-2000, CE, CB, CCC Function: Conventional Circuit Breaker, RCCB Type: RCCB Poles Number: 3,4 Structure: MCCB Installation: Fixed Arc-extinguishing Medium: Air Speed: High-Speed Circuit Breaker Operation: Electric Type Breaking Capacity: Low Voltage Circuit Breakers Model: mm1l Number of Poles: 3p, 4p Current Value: 100A~1600A Trademark: Long Road/OEM Transport Package: Carton Specification: IEC60947-2 Origin: China Product Description 1.ApplicationMM1L series earth leakage circuit breakerare one of the new type earth leakage breakers which have been developed by the company using international advanced design and manufacturing technology. Suitable for a line of AC50Hz/60Hz, rated voltage up to 400V, rated current 16A to 630A. and is acted as infrequent changeover of circuit or infrequent starting of motor. The breaker has overload, short-circuit and under-voltage protective function, which can protect the circuit and the power equipment against damage, meanwhile, it can provide protection to these fire dangers that caused by these long-time existed grounding fault that can not be detected by the over-current protection.This breaker can be installed vertically(upright) or horizontally(transverse).Wiring of the breaker can not be in adverse direction, that means power supply line must be connected to terminal 1,3 and 5,and the load line connected to terminal 2,4 and 6.The rated residual operating current I△n and the maximum breaking time can be adjusted on site according to practical condition.The leakage protection module still can work normally when the phase voltage reduce to 50V. It has the same overall size with the AM1 series breakers, which make the installation more exchangeable.The breakers are suitable for isolation, its symbol are:The breakers comply with the demands of the following standards:IEC60947-1 and GB/T 14048.1 GeneralIEC60947-2 and GB 14048.2 Low voltage breakersIEC60947-4 and GB 14048.4 Contactors and motor startersIEC60947-5.1 and GB 14048.5 Electrical equipments of electromechanical control circuit2. Main Technical SpecificationsTypeMM1L-100MM1L-225MM1L-400MM1L-630frame Current Inm(A)100225400630Rated current In(A)(10)16,20,25,32,40,50,63,80,100100,125,160,180,200,225225,250,315,350,400400,500,630Pole Number34343434Rated Insulation Voltage Ui(V)AC800Rated Working voltage Ue(V)AC 400VRated impulse with stand voltage Uimp(V)8000Arc-over Distance(mm)>50Breaking capacity gradeMHMHMMLimiting short-circuit breaking capacity lcu (kA)AC400V5085505085506565Service short-circuit breaking capacity lcs(kA)AC400V3550353550354242Rated residual operating current I△n(mA)Non-delay type100/300/500Delay type100/300/500300/500/1000Rated residual nonoperatingcurrent I△no(mA)1/2 I△nOperation performance (time)Electrified1500100010001000Unelectrified8500700040004000Note: According to the pole number of product, it calssifies three and four poles. The neutral pole (N-Pole) of the four-poles products has four types:Type A: N-pole without over-current release unit, it has been connected all the time, not closing and opening with the other three poles.Type B: N-pole without over-current release unit, which closing and opening with the other three poles.Type C: N-pole fixed with over-current release unit, which closing and opening with the other three poles.Type D: N-pole fixed with over-current release unit, it has been connected all the time, not closing and opening with the other three poles.1. The limiting breaking and arc-over distance includes horizontal and vertical installation.2. If the three-pole breaker of this series is connected with three phase load, the load can not have neutral line, otherwise the breaker will have fault action.3. If the three-pole breaker of this series is connected with single phase load, the phase line willbe connected to the left pole, and the neutral line is connected to the right pole, the middle pole is blanket3. Protection CharacteristicThe thermal release of the breaker has again-time-limit property; the electromagnetic release is inst. Operation, its property see table 2(for distribution),table 3 (motor protection).Rated current of Release(A)Thermal release (ambient temperature+40oC)Electromagnetic release operating current(A)1.05In(cold state ) non-operating time (h)1.03In(hot state) acting time (h)10 ≤ In ≤ 631110In±20%63 ≤ In ≤ 12522125 ≤ In ≤ 630225In±20% 10In±20%Rated current of ReleaseThermal release (ambient temperature +40oC)Electromagnetic Release operating current(A)1.0In (cold state) non-operating time(h)1.20In(hot state) acting time(h)1.50In(thermal state) operating time7.2In(cold state) operating time10≤In≤400228min6s < TP ≤ 20S12In±20%4. Residual current operating time of earth leakage circuit breaker4.1 Non-delay type operation characteristics see table 4(I△n≤30mA should be Non- delay type)Rated currentI△n2I△n5I△na10I△nNon-delay typeMax.breaking time(s)0.30.150.040.04Note: ato I△n≤30mA earth leakage circuit breaker, 0.25A can instead of 5I△n According toa, adopt 0.25A, then 10 I△n is 0.5A.4.2 Delay type operation characteristics see table 5Limiting non-driven time of delay type earth leakage circuit breaker according to 2l△n,operation characteristics see table 5Delay time (s)Max. breaking time(s) at I△nLimiting non-driven time (s) at 2 I△nMax. breaking time(s)Max. breaking time(s) at 5I△nMax. breaking time(s) at 10 I△n0.10.40.060.20.150.150.20.50.060.20.150.150.30.60.10.40.3-0.40.70.20.50.4-0.50.80.30.60.5-0.60.90.40.70.6-0.71.00.50.80.7-5 .Accessories of circuit breaker5.1 The external accessories of the breakerMotor-driven operation device1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1L-100,225) see thefollowing drawing (wiring diagram of the external accessories of the breaker in the dotted frame)2) Wiring diagram of type CD motor-driven operation device (fitting AM1L-400I630) see belows(wiring diagram of the external accessories of the breaker in the dotted frame)Code description: SB1 SB2 stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.Voltage rating: AC50Hz 230V 400V, DC 220VCode description: SB1 SB2 stand for push button. (provided by users themselves) "X" stands for line connection terminalsVoltage rating: AC50Hz 230V 400V; DC220VRotary handle operation device The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation one is "A" modelsquare handle , the other is "B" model round handle.5.2 The internal accessories of the breaker5.2.1 Release pattern and accessories code see following tableRelease patternand accessories codeNameTypeMM1L- 100,225MM1L-400MM1L-630200, 300No accessories200: Magnetic release (only short circuit protection)300: Thermal magnetic release(both overload and short circuit protection)208, 308Alarm contact210, 310Shunt release220, 320Auxiliary contact230, 330Under-voltage release228, 328Auxiliary contact,Alarm contact5.2.2 The technical parameter and functions of the accessoriesAccessoryRated operating voltage (V)AC50HzDCShunt Release Us220(230)380(400)110220Under-voltage Release Us220(230)380(400)Auxiliary contact and Alarm contact: Auxiliary contact is as some as Alarm contact , the techni-cal parameter see following tableRated heating current Ith (A)Rated operating current Ie(A)Suited frame Inm(A)AC380VDC220V30.30.15100, 22530.40.15400, 630Accessories nameFunctionWiring connection diagramAlarm contactIndicate circuit breaker at trippingAuxiliary contactIndicate circuit breaker at opening or closingShunt releaseThe shunt release should make the breaker trip reliably when theoperatiopn voltage is 70%-110% of rated control voltageUnder-voltageWhen Ue is 35%-70% of the rated control voltage, the under voltagerelease should make the breaker trip correctlyWhen Ue is 85%-110% of the rated control voltage, the under voltagerelease should make the breaker closeIn case of Ue less than 35%of the rated control voltage should preventthe breaker from closingTypeOutline dimensionsInstallation dimensionsBack panel connectionBack panel connectionPlug-inWLHW1L1L2H1H2L3H3DL4L5H4H5H6CDD1ABdMM1L-100M,H/3P92150926020020013211028.590931689250647660566.5301294.5MM1L-100M,H/4P122150929020020013210428.590931689250647660566.5301294.5MM1L-225M,H/3P10716590702652651441102493100183945071.586.590546.5351265.5MM1L-225M,H/4P14216510310526526514412724931001839450710.586.570546.5351265.5MM1L-400M,H/3P150257106.596441441224146.538164108.5279-6083.5106.51051298.5441947MM1L-400M,H/4P198257106.5144441441224146.538164108.5279-6083.5106.5701298.5441947MM1L-630M,H/3P210280115.514548048024315545.315884296-619714814014310702437MM1L-630M,H/4P280280115.521048048024315545.515884296-619714821014310702437
举报收藏 0
更多>本企业其它产品
Miniature Circuit Breaker Model Lr-3p1m002 Fibreglass Materials 3 Phase Kwh Meter Box DIN-Rail Mounting Type Single Phase Electronic Energy Meter DIN-Rail Mounting Rated Current 100A Miniature RCCB with Short-Circuit Breaking 10ka 6000A Short Circuit Breaking Capacity 1p+N RCBO 26mm Width Compact Miniature Circuit Breaker 6000A Short Circuit Breaking Auto on/off 100A 3p+N MCB Surge Protective Device Srsd-I-Serise Type I Surge Arrester
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报