Full Inverter Swimming Pool Heat Pump

 
 
单价 800.00 / Piece对比
销量 暂无
浏览 284
发货 Chinaguangdongshenzhen
库存 2000Piece
过期 长期有效
更新 2020-08-18 14:47
 
联系方式
加关注0

Shenzhen Eurostars Technology Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Full Inverter Swimming Pool Heat Pump Model NO.: ESSA-10HP(2*4.5ES) Heat Source Type: Air Source Heat Pump Working Medium: R410A Certification: ISO9001, CE Compressor: Copeland/Panasonic Water Side Heat Exchanger: Titanium Tube-in-Shell Heat Exchanger Air Side Heat Exchanger: Blue Aluminum Fin Copper Tube DC Inverter: Optional Working Ambient Termp.: -7deg C~43deg C Warranty: 2 Years, 18 Months, 1 Year Overseas Service: Available Throttle Unit: Electric Expansion Valve Power Supply: 50Hz, 60Hz(Optional) OEM,ODM: Available Power Source: Electric Housing Material: Galvanized Steel Structure: Monoblock Type Application: Pool Water Cooling and Heating Refrigerant: R410A Trademark: ESACIR Transport Package: Standard Export Package Specification: CE Origin: Guangdong, China HS Code: 8418692090 Product Description 1.Application of Air Source Swimming Pool Heat PumpEurosatrs House Spa and Commercial Swimming Pool Heat pump are specially developed for commercial pool or spa water temperature control. With intelligent control system are let the units high efficiency and stable working performance. The COP of this type heat pump can reach 5~ 5.4 at some working condition, which saves you at least 80% energy;Suitable for large pools in hotel, public parks, schools, sport center, gyms, house spa, etc.2.Eurostars Air Source Swimming Pool Heat Pump Features:Eurosatrs Swimming Pool Air Source Heat Pumps are designed for commercial pool water heating.They have the following important features:--Constant pool water temperature;--Absorb heat from the air with high COP;--Working air temperature range: -7ºC to 43ºC;--Automatic control of pool water temperature;--Max outlet water temperature: 40ºC;--Guaranteed safety: water and electricity are isolated;--Anti-corrosion with Titanium tube-in-shell heat exchanger;--Save 65%-80% of the operating costs without pollution to the environment.--Automatic and forced defrosting function;--Multiple protections 3. Air Source Swimming Pool Heat Pump Technical DataAir Source Heat Pump Unit(Swimming Pool Heat Pump)ModelESSA-05HPESSA-05HPESSA-05HPESSA-05HP2.5ES3.5ES4.5ES3.5ESHeatingAir DB/WB: 24ºC/16ºCWater tempt: 28ºCKW10.215.118.515.1x 1000 Kcal/h8.813.015.913.0RT2.94.35.34.3Input power (KW)1.942.953.602.94COP5.265.125.145.14CoolingAir DB/WB: 35ºC/24ºCWater tempt: 28ºCKW6.69.812.09.8x 1000 Kcal/h5.78.410.38.4RT1.92.83.42.8Input power (KW)2.113.213.923.20EER3.143.063.073.07Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerantR410APower Supply220~240V/50Hz380~420V/50HzModelESSA-05HPESSA-10HPESSA-10HPESSA-12.5HP4.5ES6ES2*4.5ES2*6ESHeatingAir DB/WB: 24ºC/16ºCWater tempt: 28ºCKW20.226.140.452.2x 1000 Kcal/h17.422.434.744.9RT5.77.411.514.8Input power (KW)3.965.117.9210.22COP5.105.115.105.11CoolingAir DB/WB: 35ºC/24ºCWater tempt: 28ºCKW13.117.026.333.9x 1000 Kcal/h11.314.622.629.2RT3.74.87.59.7Input power (KW)4.315.568.6211.12EER3.053.053.053.05Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerantR410APower Supply380~420V/50HzModelESSA-15HPESSA-20HPESSA-25HP2*7ES4*4.5ES4*6ESHeatingAir DB/WB: 24ºC/16ºCWater tempt: 28ºCKW60.580.8104.4x 1000 Kcal/h52.069.589.8RT17.223.029.7Input power (KW)11.9415.8420.44COP5.075.105.11CoolingAir DB/WB: 35ºC/24ºCWater tempt: 28ºCKW39.352.567.9x 1000 Kcal/h33.845.258.4RT11.214.919.3Input power (KW)12.9917.2322.24EER3.033.053.05Compressor TypeHermetic ScrollThrottle TypeExpansion ValveRefrigerantR410APower Supply380~420V/50Hz4.Air Source Swimming Pool Heat Pump Main Components IntroductionNoNameDescription1CompressorBrand: Copeland/Panasonic2Air Heat exchangerHydrophilic Aluminum foil and copper pipe with inner thread heat exchanger3Water Heat exchangerType: titanium tube in PVC shell4Expansion valveBrand: Danfoss/Sanhua or other brand,Type: Electronic type5Four way valveBrand: SANHUA, most famous in China6FanBlade: low noise and large air flow. Motor: Axial type, stable and large air flow7AC contactorBrand: EATON/FUJI/ Schneider,etc, smart action, stable quality8ControllerLCD screen, multi protections, remote control, simple operating5. EUROSTARS Air Source Scroll Heat Pump Range:(1) Water source heat pump(2) Geothermal source heat pump(3) Air source heat pump, including swimming pool heat pump(4) EVI air source heat pump (5) Split heat pump(6) DC Inverter heat pump6.about USWe, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; One Stop Solution For Your Project:-- Project Consultation--Professional Customized Design & Planning--Supply Full Set Optimum Equipment & Accessary Accordingly--Whole Project Installation & Commissioning--Project Running Management, Engineer and Operator Training, Turnkey--Long Life Quality Assurance & Maintenance7.FAQQ:How does the Swimming Pool Heat Pump Work?Heat pumps use a small amount of driven electricity to absorb heat and transport it from one place to another. Indeed, they couldn't generate heat.As swimming pool's water circulated by the pool pump, the water get from the pool passes through a filter and pool heater. The pool heater has a fan that brings in the outside air and guides it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside and then evaporate gas. The evaporated gas in the coil then flows through the compressor. The compressor pump to increase the heat, generate a very hot gas that then flows through the condenser. The condenser moves the heat from the hot gas to heat the cooler pool water circulating through the heater. The heated water then flow into the pool. The hot gas, as cross flows through the condenser coil, back to liquid form and return the evaporator, where the whole process begins again.Higher efficiency heat pump pool heaters usually use scroll compressors versus the rotary compressors of standard composition.Heat pump pool heaters work efficiently as long as the outside temperature remains above the 7ºC-10ºC range. The cooler the outside air they bring in, the more energy they exhaust. However, since most people adopt outdoor swimming pools during summer or mild weather, this usually isn't an issue.8.Customer visit us9.Air source heat pump delivery or container loading10.Installation instruction or installation photo, project photosA,Place selection of installationHeat pump1). Heat pump should be installed in a large space, and have good air flow condition.2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.3). Set drain ditch or drain outlet, so that can drain water easily.4). The installation base or bracket must be firm, make sure heat pump work balancely.5). Make sure heat pump is vertical, can't be slanted.6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.7). The installation place can't be near inflammable, flammable thing or fire.8). Installation:---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.---The design of installation base can be according to heat pump weight.---The heat pump bottom should be fixed by bolt.B,Pipe connectionThe drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipebefore magnetic valve there should be service valve on water pipe.If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.C,Water pipe system installationWater pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.There can't be leaking at any place of pipe.After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is clean. After confirm there isnot any problem, then insulate all hot water pipes.D,Power supply wiring220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.1).When repairing, please turn power supply at "off" side.2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switchatsuitable place, Use rubber hole for wiring line in electric box.Power supply demand:220V rated voltage±10%380V rated voltage±10%frequency:50Hz rated frequency±2%3).if power supply fluctuation is out of demand, please don't start your heat pump.
举报收藏 0
更多>本企业其它产品
2.8kw Ultrathin Designed Heat Pump Floor Mounted Fan Coil Vertical Return Air Floor Mounted Air Conditioning Fan Coil Make up Clean Fresh Air Handling Unit Resh Air Ventilation Systems 12.6kw Large Air Flow Vertical Exposed Floor Standing Fan Coil Hotel Air conditioner Monoblock Water to Water Geothermal Heat Pump 110kw Ultra Low Ambient Temp. Heat Pump Water Heater Monoblock Air to Water Cooler Heater Heat Pump
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报