Dw45 Air Circuit Breaker

 
 
单价 10.00 / Piece对比
销量 暂无
浏览 104
发货 Chinazhejiangwenzhou
库存 5000Piece
过期 长期有效
更新 2020-08-18 05:24
 
联系方式
加关注0

Elecal Electric Appliance Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: Dw45 Air Circuit Breaker Model NO.: DW45 Certification: CE Function: Conventional Circuit Breaker Type: Circuit Breaker Poles Number: 4 Structure: ACB Installation: Fixed Arc-extinguishing Medium: Air Speed: High-Speed Circuit Breaker Operation: Electric Type Breaking Capacity: Low Voltage Circuit Breakers Trademark: ELECAL Transport Package: Carton Origin: Wenzhou Product Description DW45 series air circuit breaker(hereinafter referred to as breaker)is suitable for the circuit of AC 50Hz with rated voltage 400 V,690V and rated current up to 6300A.It is mainly used to distribute electric energy and protect circuits and power-supply equipment from over-load,under-voltage,short-circuit and single-phase earthing.with intelligentized and selective protection functions,the breaker can improve the reliability of power supply,and avoid unnecessary power failure. The breaker is applicable for power stations,factories,mines(for 690V) and modern high-buildings,especially for the distribution system of intelligentized building.This breaker conforms to IEC60947-2 and GB14048.2.Environment conditions for operation:Environmental temperature Tempeerature condition:-5oC ~+40oC ;the average value within 24h shall not exceed +35(Speial situation excluded )Elevation Altnmosphere condition Relative humidity at +40oC. shall not exceed 50%.higher hum-idity is permissible at lower temperature condition. when the highest monthly average relative humidity is 90% in the humiddext month,the lowest monthly average temperature of this month is +25oC.And consider the influence of dew on product surface due to temperature changes.pollution grade:grade The breaker should be installed caccording to the requirements on the instruction manual.The vertical inclination degree shall not exceed 5oStructure:Drawer type breaker and fixed type breakerThe breaker consists of body and drawer base.inserting the body into the drawer base, thus make the drawer-type breakerInstallation and usage :Installation Unload the breaker from the soleplate of package-box. if it is drawer type,firstly pull out the handle from under the drawer-base of breaker,and plug it into the hole on central section of plastic cover under the drawer-base crossbeam,anticlockwise turns the handle,breaker body will slowly slide along the outside of drawer-base. When the guide-rod points to separated position and handle can't be rotated any longer,pull out the handle and firmly grasp the aluminum hadle on drawer-base,pull out the breaker body and remove ift form drawer-base Check the insulation resistance with a 500V megger,resistance should not be less than 20MQ when ambient temperature is 20oC5oCand relative humidity is 50%-70%.otherwise have it drying. Put the breaker(fixed-type) or drawer-base(drawer-type) onto the installation- bracket,and make it fixed,directly connect the bus wire of main circuit to the bus wire of fixed-type circuit breaker,alternatively put breaker body onto the guild rail of drawer-base.Plug the place,then connect the bus wire of main circuit to bus wire of drawer-base. wiring the secondary circuit according to electric principle diagram. Note:something like bolts,nuts.gaskets shouldn't be left inside the drawer-base to avoid being blocked. Usage and operation Check the rated voltage of the following components whetherconforms to the power voltage or not .such as under voltage release,shunt releaseclosing electromagnet,motor-driven mechanism and intelligent controller Maintenance Check the technical index on time or and some lubricating oil.,etc. This breaker structure is arranged vertically and modularized composition with each function=cell separated,which make the maintenance easy.it has compact structure,reliable operation and strong free maintenance capability. P lease check the technical parameters on the nameplate accordance with the reauirements of order before installationProduct model and its meaning :Making the secondary circuit power,the motor-driven menchanism can store eenergy automatically until hearing the click and energy stored "indicating on the panel. otherwise press the storage handle for 6 times until hearing the click and the indicator display energy stored" and the closing operation can be realized either by closing electromagnet or manual button.DW45-1000Main teachnical parameter:Rated ultimate short circuit breaking capacity(KA) lcu=42KA 400V 20KA 690Vlcu=lcw=30KA 400V 15KA 690V Rated current in (A)200 400 630 800 1000 Number of poles3,4Rated voltage ue(V)400V,690VRated insulation voltage Ui (A)1000VRated current of N-pole IN(A)50%In,100%INFixed disconnection time 23-32MsIntelligent controllersandard type(M)Communication type(H)Operation performance Electric life500mechanical lifeNon-maintenance 2500Maintenance 10000Connection pattern Horizontal,verticalDW45-2000Main teachnical parameter:Rated ultimate short circuit breaking capacity(KA) lcu=80KA 400V 50KA 690Vlcs=lcw=50KA 690V 40KA 690V Rated current in (A)400 630 800 1000 1250 1600 2000 Number of poles3,4Rated voltage ue(V)400V,690VRated insulation voltage Ui (A)1000VRated current of N-pole IN(A)50%In,100%INFixed disconnection time 23-32MsIntelligent controllersandard type(M)Communication type(H)Operation performance Electric life500mechanical lifeNon-maintenance 2500Maintenance 10000Connection pattern Horizontal,verticalDW45-3200 DW45-4000 Rated ultimate short circuit breaking capacity(KA) lcu=100KA 400V 80KA 690Vlcs=lcw=80KA 400V 40KA 690V Rated current in (A)2000 2500 3200 4000 Number of poles3, 4 3Rated voltage ue(V)400V,690VRated insulation voltage Ui (A)1000VRated current of N-pole IN(A)50%In,100%INFixed disconnection time 23-32MsIntelligent controllersandard type(M)Communication type(H)Operation performance Electric life500mechanical lifeNon-maintenance 2500Maintenance 10000Connection pattern Horizontal,verticalDW45-6300Rated ultimate short circuit breaking capacity(KA) lcu=120KA 400V 80KA 690Vlcs=lcw=100KA 400V 60KA 690V Rated current in (A)4000 5000 6300 Number of poles3, 4 3Rated voltage ue(V)400V,690VRated insulation voltage Ui (A)1000VRated current of N-pole IN(A)50%In,100%INFixed disconnection time 23-32MsIntelligent controllersandard type(M)Communication type(H)Operation performance Electric life500mechanical lifeNon-maintenance 2500Maintenance 10000Connection pattern Horizontal,vertical
举报收藏 0
更多>本企业其它产品
AC-Axial Fan Axial AC Fan Ta12025 Series Type B RCBO RCCB Residual Current Breaker Wall Switch  Wall Socket of I Series Sup1 Surge Protective Device Dz48n-63 Series Miniature Circuit Breaker SVC-D (LCD) Series Fully Automatic a. C. Voltage Regulator Waterproof Industrial Plug IP44 Round 4pins Power Plug 16A 220-250V 3p+E Male and Female Pairs of Pl
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报