Construction Building Hoist Communication Intercom Speaker System for Building Hoist Floor Call Syst

 
 
单价 1.00 / Piece对比
销量 暂无
浏览 44
发货 Chinashanghai
库存 30000Piece
过期 长期有效
更新 2020-08-20 14:07
 
联系方式
加关注0

Shanghai Strong Engineering Construction Co., Ltd.

企业会员第6年
资料未认证
保证金未缴纳
详细说明
Product Name: Construction Building Hoist Communication Intercom Speaker System for Building Hoist Floor Call System Model NO.: HC2.0 Condition: New Certification: CE, ISO Information content: Voice Type: Wired Usage: Telephone, Workstation, Server, Mobile phone Frequency: 3 Kinds Quantity: Depends on Floors Trademark: STRONG Transport Package: Carton Box Specification: the phone is 200*120*50mm Origin: Shanghai HS Code: 84313900 Product Description Product DescriptionSpecifically designed and manufactured to provide CRYSTAL CLEAR, communications to help create a safer work environment, which increases PRODUCTIVITY and lowers the risk of LIABILITY.Construction hoist intercom speaker system.Safety FirstMainly used on construction and temporary Hoists/Elevators, it is recommended by OSHA, and also considered the industry standard in the USA, Canada and Australia.Communications is critical to provide workers a way to contact the elevator operator in case of an emergency. When a worker is hurt or suffers a heart attack, seconds count to get medical attention to that person.Also as a general intercom system, allowing supervisors and workers to locate and communicate with each other. The down time that it takes to find personnel and to manage workers is reduced tremendously, thereby adding to the profit of the project.Intercom system Overview- All units interchangeable.- No antenna wire required.- Two way communications.- Volume controlled Car Units.- Powered by safe 24 volts DC.- Multiple frequency channels.- Emergency alarm switches on all units.- Operates in extreme weather conditions.- Backup battery power supply for Car unit.- Heavy duty composite Nylon Plastic enclosure.- Up to 3 Multiple Frequency channels selection.- Microphone gain adjustment, for control of feedback.- Mute function, limits amount of Com units that broadcast.Made in the ChinaThis product is designed and made in the China. Our products incorporate the latest technology and are built with strict quality control in order to guarantee reliability and performance. Recommended by OSHA.INTRODUCTIONSite:Used in the industrial elevator of the building elevator and the construction hoistFunction:Provides an emergency call between the construction of the floor inside the building and elevator driver. Greatly improves the production efficiency, and effectively prevent accidentsStrength:Used in the construction of the elevator intensive areas of reliable use(the radio frequency needn't apply)FUNCTIonAL FEATUREThe signal transmission is carried out by using the protection loop line. the signal isstable and reliable, and the special communication cable is not required.The signal line and power line are not connected with high voltage, and the system is safe and reliable.No electromagnetic wave pollution, do not need to apply for radio frequency, andcan be used in the construction of the elevator intensive and authentic and other construction areas, and will not affect each other.Press the button for intercom function. It can prompt the communication is busy. Italso has the squelch function.Electronic volume control, convenient volume adjustment.There is an alarm button, can be used in emergency.Three frequencies available, voice clear and natural. SPECIFICATION PARAMETERSupply Voltage:220V AC or 110V ACEffective Range:more than 300m(Conductor loop resistance<600 ohm)Three Frequencies Available:250KHz,741KHz or 800KHzSYSTEM INSTALLATIonInstallation instructions for each floorThe installation method of the intercom on each floor can be referenced to the left of the following view. Fit the intercom and connect the intercom with the accessory power cable. Note: adedicated power supply device can only drive less than twenty. In accordance with the drawings, another port dedicated power supply connected to the junction box, and then connected to the coupler. In the first floor of the construction elevator, the protective ground wire passes through the hole of the coupler, and it is connected with the ground. important note for installation, in the communication system, the protective grounding wire passing through the coupler can not be grounded in the middle ground.Installation instructions in the lifting cage of construction hoistThe installation method of the cage intercom see below right view. In accordance with the drawings, connect the intercom, the call device power supply, and the coupler. In the lift cage, the protective ground wire passes through the hole of the coupler, and it is connected with the ground.Description of terminal of special power supply device:NOCableExplain1LPower(blue)2NPower(brown)Three core cable3GGround(yellow)4-VCable shield5-VNegative power(brown)The four core shielded6+VPositive power(black)cable7+VPositive power(blue) COMMON USAGE ISSUESANDEXPLAINFAQExplainCommunication FailureThe protective ground wire of the coupler is grounded in the middle ground, and the protective earth wire and the ground wire in the hanging basket are not connected.Poor communicationHigh resistance caused by ground wiring and/or poor connection.Interference caused by electric motorCables require better sheielding.
举报收藏 0
更多>本企业其它产品
Construction Hoists Hoistcom Call System Elevator of Building Site Wireless Calling System  Waterproof Call Button Construction Building Hoist Communication Intercom Speaker System for Building Hoist Floor Call Syst Wireless Queue Management System Calling Intercom System Solar Warning Strobe Light  Signal Light Construction Signal Lamp Magnet Solar Warning Light New Red LED Warning Solar Tower Crane Obstacle Strobe Light Rotary Blowing Flash/Blink 8 LEDs Construction Obstruction Light for Tower Crane
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报