China Plunger for for Alstom Valve Optipow 135

 
 
单价 50.00 / Pieces对比
销量 暂无
浏览 205
发货 Chinashandongqingdao
库存 2000000000Pieces
过期 长期有效
更新 2020-04-05 22:28
 
联系方式
加关注0

Qingdao Star Machine Technology Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: China Plunger for for Alstom Valve Optipow 135 Model NO.: V3629022-0100 Trademark: SMCC OR NO MARK Transport Package: According to Customer Requirements Specification: 910mm*340mm*29mm Origin: China HS Code: 8413910000 Product Description ALSTOMmodelOPTIPOWpistonpulsecleaningvalveOPTIPOW135(24V)V1614718-0100OPTIPOW135(100V,50Hz)V1614718-0301OPTIPOW135(120V60Hz)V1614718-0400OPTIPOW135(120V60HzUL-CERTIFIED)V1614718-0700OPTIPOW135(withoutsolenoid,revolving90°C)V1614718-0800-MembraneV4549902-0100O-Ring(Fluorrubber64,5x3)8003-5573O-Ring(Nitril70SH64,5x3)2136-1422O-Ring(114,5x3)2136-1441PilotcoverV3630501-0100PlateV3630524-0100PlungerV3629022-0100Roundwasher(SS3576-5-200HVFE/ZN25)4903-2146-RubberdiscV3640660-0100Solenoidvalve(24VDC)V3611471-0100Solenoidvalve(100V,60Hz)V3611471-0201Solenoidvalve(110V,50Hz)V3611471-0300Solenoidvalve(110V,60Hz)V3611471-0200Solenoidvalve(120V,60Hz)V3611471-0400Solenoidvalve(120V,60Hz-ULCERTIFIEALSTOM'snewOPTIPOWcompactpistonpulsecleaningvalveALSTOM'sOPTIPOWnewcompactpistonpulsecleaningvalveismainlyusedforbagcleaningandinstallationonarounddrum.Lowlossofcompressedair:TheOPTIPOWpulsevalvereducestheamountofcompressedairconsumedcomparedtothediaphragmtype.OPTIPOW135 Valve V1614718-0100 filter QIU-40One overview:The pulse control instrument is the main control device of the pulsing bag dust remover system. The output signal controls the pulse solenoid valve. It is the circulating dust of the filter bag by the injection and compressed air, and the resistance of the dust collector is kept in the setting range, so as to ensure the handling capacity and the dust absorption efficiency of the dust collector.The pulse jet controller outputs a continuous electrical signal time, which is the pulse width. The time between output of two signals is called pulse interval. The time required for the controller to output the electrical signal to complete a cycle is called the pulse period.Two technical indicators:1. The rated input voltage is AC220V (1 + 10%).2, rated output voltage DC24V (or AC220V)3. The output pulse interval adjustment range is 1~999 seconds4. The range of output pulse width is 0.01 to 99 seconds5. The output pulse cycle adjustment range is 0~99 minutes6, outline size: 10 road -160*160*90mm, 20 road -230*160*90mm, 30 road -260*180*100mmThree connection mode20 way connection modeLNTOTAL12345678910…20The 'power' terminal is 220V input, and the 'public end' terminal is the output connection common line for the pulse valve. '1-12' is sequentially connected to the pulse valve, and the 'running signal' and 'AB' are not connected.Four methods of use:1, pulse width setting: (unit: 0.01 seconds; maximum value of 99 seconds) press red function key, make pulse width indicator light, rotating black setting key directly adjust to the time required.2, the pulse interval setting: (unit: 1 second; the maximum value is 9999 seconds) press the function key to make the interval indicator light, and the rotation setting key is directly adjusted to the time required.3, the pulse cycle setting: (unit: 10 seconds; the maximum value of 99 minutes) press the function key to make the cycle light light, and the rotation setting key is directly adjusted to the time required.4, output path setting: press the function key to make the output path indicator light, and the rotation setting key directly adjust to the required number.Five, maintenance and maintenance1. After installation and use of the control instrument, special personnel should be responsible for the maintenance. Every day, check the operation situation and find out the malfunction in time.2. The controller is connected to the power supply and the indicator light is not bright. Check whether the power cord on the wiring terminal is loose and whether the fuse is normal.3, the controller displays normal, a pulse valve is always open, check whether the corresponding electronic switch is damaged.4, the controller displays normal, and the two electromagnetic pulse valve works at the same time.5, the controller displays normal, the solenoid valve does not work, check whether the public terminal of the output terminal is reliable.6, digital tube flicker, check whether the fuse is loose, and whether the power supply is normal.Our products are mainly exported to Brazil,Vietnam, Korea, Chile, Canada, Thailand and other countries and regions, Among whom we have very good reputation for many years.If you have any need please send your enquiry to us, We would provide you with the best products, the most competitive prices and the best services.
举报收藏 0
更多>本企业其它产品
Stainless Steel Sprocket for Motorcycle Parts Stainless Steel Sprocket for Machine Custom Industrial Automation Conveyor Sprockets Customized Industrial Gear Sprocket Industrial Chain Sprocket ANSI DIN ISO JIS Standard Plate Sprockets Alstom Optipow 135 Fabric Filter Cleaning Valve Without Solenoid Revolving 90 C China Diaphragm of Piston Pulse Alstom Optipow Cleaning Vanne
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报