Acrel Bd-3I3 AC Three Phase Elecreical Current Transducer Isolate AC Current to Analog 4-20mA/0-5V O

 
 
单价 84.00 / Piece对比
销量 暂无
浏览 54
发货 Chinajiangxijian
库存 1000Piece
过期 长期有效
更新 2020-08-08 11:56
 
联系方式
加关注0

Jiangsu Acrel Electrical Manufacturing Co., Ltd.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Acrel Bd-3I3 AC Three Phase Elecreical Current Transducer Isolate AC Current to Analog 4-20mA/0-5V Output Model NO.: BD-3I3 Customized: Non-Customized Certification: CE Application: Industry Automation Accuracy Grade: 0.5G Material: metal Production Process: Injection Output Signal Type: Analog Output Type: Electromagnetic Product Name: Three Phase Current Transducer Brand: OEM ODM Current Range: AC 0-5A Output: 4-20mA Accuracy: Class 0.5 Auxiliary Power Supply: AC85-265V/DC 100V~350V/DC24V/DC 28V Installation: Ts35mm DIN Rail Type Trademark: ACREL Transport Package: Fob Shanghai Origin: China Product Description Product DescriptionBD-AI Single Phase Current TransducerGeneralBD series current transducer isolate and convert electrical parameters(e.g.current,voltage,frequency,power and power factor) in the power grid into DC analog signal or digital signal.The product complies with GB/T13850-1998 and IEC-688.Features- Measure AC current- Overload: 1.2 times of rated value- Analog Output DC 0-5V/0-10V/0-20mA/4-20mA-RS485 (Modbus-RTU)communication-Power monitoring applicationTechnical ParametersTechnical parametersValueAccuracy 0.5class,0.2classInputNominal valueCurrent :AC,DC 1A,5A;Voltage: AC,DC 100V,300V,500Vand so onOverloadContinual 1.2 times, Instantaneous current 10 times/5s;Instantaneous voltage 2 times /30sAbsorbed power≤0.3VA(Current input);Voltage input≤0.3VA(100V),≤0.6VA(300V),≤1VA(500V)Frequency50±5Hz,60±5HzOutputNominal valueDC:4-20mA,0-20mA, 0-5V, 0-10Vand so onLoad ResistanceCurrent output ≤600ΩVoltage output ≥1000ΩRipple content<0.5% peak valueResponse time≤400msPower supplyVoltageAC85-265V/DC100-350V/DC24V/DC48VPowerAC current, Voltage class ≤3VA,Power Class ≤4VAInsulation Resistance≥100MΩIsolation voltage(Among input//output//power supply)2.0kV/1min,50HzTemperature coefficient0.5class≤200ppm/ºC; 0.2class≤100ppm/ºCE EnvironmentTemperatureWorking:-10ºC~+55ºCStorage:-25ºC~+70ºCHumidity≤90%RH,(In the place without dew and corrosive gas)Altitude≤2000mInstallation(TS35 rail mounting, or attached with screws in of the cabinet)TypesNameModelFunctionOptional FunctionCurrent TransmitterBD-AIMeasurement of single-phase AC current, isolation transmission output 4-20mA or 0-5V DC signalRS485-MODBUS(C)BD-3I3Measurement of three-phase alternating currents transmission output isolation 4-20mA or 0-5V DC signal/Voltage transmitterBD-AVMeasuring AC voltage isolation transmission output 4-20mA or 0-5V DC signalRS485-MODBUS(C)BD-3V3Three-phase three-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signal/BD-4V3Phase four-wire voltage transmitter, measuring three-phase AC voltage isolation transmission output 4-20mA or 0-5V DC signalPower transmitterBD-4EAThree-Phase four-wire multi-power transmitter, measuring and displaying exports three-phase current, voltage ,active power, reactive power ,frequency ,power factor, active energy; reactive energy and so on, 1~4 channel analog optional, two channel electric energypulse output,RS485-MODBUSM- Analog output, selectable 1 channel, 2- channel, 3- channel, 4- channelFrequency transmitterBD-FMeasure frequency, transmit frequency into linear DC signal output/Active power transmitterBD-3PThree-Phase 3-wire,Measurement of active power, isolation analog signal transmission output/BD-4PThree-Phase 4-wire,Measurement of active power, isolation analog signal transmission output/Reactive power transducerBD-3QThree-Phase 3-wire,Measurement of reactive power, isolation analog signal transmission output/BD-4QThree-Phase 4-wire,Measurement of reactive power, isolation analog signal transmission output/P / Q combination transmitterBD-3P/Q/IThree-Phase 3-wire,Measuring current, active power, reactive power, isolate analog signal transmission output/Dimension(Unit:mm)Wiring Power Supply:AC85~265V DC100~350V Certificate
举报收藏 0
更多>本企业其它产品
Acrel Aim-M10 Hopital Medical It Insulation Power Supply IPS System Groud Fault Detector Device Insu Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolate Acrel Aim-M200 300286. Sz Medical It IPS Unearthed System Insulation Monitoring Equipment Acrel Ba10-Ai/V AC 0-50A Current Single Phase Current Transducer with Analog 0-5V Output Acrel Power Management Statistical Single Phase DIN Rail Electricity Meter Energy Meter Adl100-Et Amc96L-E4/Kc AC Three Phase 3p4w Digital Multifunction Programmable Smart Intelligent Electric RS485 Acrel Whd48-11 48*48mm Small Size Industrial One Channel Digital Temperature and Humidity Controller Acrel Adl300-Eyrf 1 (6) a or 10 (80) a Input Three Phase Local Prepaid Energy Meter with Radio Frequ
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报