详细说明
Product Name: Acrel 300286. Sz Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System Model NO.: AIM-M100 Optional Function(1): Double Communication Optional Function(2): Fault Alarm Output Optional Function(3): Temperature Monitoring Optional Function(4): Load Monitoring Optional Function(5): Centralized Monitoring Software Optional Function(6): Desconnection Monitoring Optional Function(7): Soe Fault Record Optional Function(8): Self-Test Trademark: ACREL Transport Package: Fob Shanghai Origin: China Product Description Product DescriptionAIM-M100 Medical Intelligent Insulation Monitor for Medical Insulation SystemGeneralHealthcare OT operating theater isolation power systems / IPS for electrical safetyMedical insulation monitoring device adopts advanced microcontroller technology, which has high integration, compact size,convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.Features* real-time monitoring and fault alarming of the ground insulation resistance,* transformer load current and transformer winding temperature of the monitored IT system,* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there areinsulation faults,* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding linedisconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,* relay alarm output, LED alarm indication and other faults indication functions,* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer managementsoftware communications, and can monitor the operation status of IT system in real time.* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel toanalyze the operation conditions of system and promptly eliminate the faults.Technical ParametersModelAIM-M100VoltageAC220V( fluctuation range ±10%)Frequency50/60HzMax power consumption<8VAInsulation resistance measuring range10~999kΩRelative percentage accuracy0~±10%Alarm value range50~999kΩResponse time<2SMeasuring voltage<12VMeasuring current<50μAMeasuring range2.1~50AAlarm value range5~50AMeasuring accuracyclass 5DisplayDigital and percentage displaythermal resistorPT100Measuring range-50ºC~+200ºC'Alarm value range0ºC~+200ºC'Output type2 channel relay output(unable to program)Contact ratingAC 250V/3A DC30V/3AWorking temperature-10ºC~+55ºC'Storage temperature-20ºC+70ºC'Relative humidity5%~95%,non-condensingAltitude≤2500mDimension(Unit:mm)WiringTypical ConnectionCertificate