Aas Atomic Absorption Spectrophotometer with Flame Detector System

 
 
单价 6.00 / Piece对比
销量 暂无
浏览 31
发货 Chinahenanzhengzhou
库存 1000Piece
过期 长期有效
更新 2020-05-06 18:20
 
联系方式
加关注0

Zhengzhou Laboao Instrument Equipment Co., Ltd.

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: Aas Atomic Absorption Spectrophotometer with Flame Detector System Model NO.: AA-320N Customized: Customized Certification: RoHS, ISO9001, CE Light Number: Polychromator Dispersive Element: Prism Spectrometer Wavelengths: UV Spectrometer Principle: Classic Spectrometer Advantage: High Sensitive Detection Method: Spectrophotometer Warranty: > 1Year Application: Laboratory Apparatus Product Name: Flame Atomic Absorption Spectrometer Usage: Determines The Presence of metals in Liquid Sample Applications: Biochemistry, Geology, metallurgy, Food Wavelength Range: 190nm-900nm Bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm Display: LCD Optics: Double Beam Interface: RS232 Printer: Optional Options: Graphite Furnace System, Hydride Generator Delivery Time: in Stock Certificate: Ce; ISO Package: Standard Export Case Trademark: LABOAO Transport Package: Standard Plywood Export Case Specification: 190nm-900nm Origin: China HS Code: 9027300000 Product Description AAS atomic absorption spectrophotometer with flame detector systemAtomic absorption spectroscopy (AAS) is a spectroanalytical procedure for the quantitative determination of chemical elements using the absorption of optical radiation (light) by free atoms in the gaseous state. Atomic absorption spectroscopy is based on absorption of light by free metallic ions.AA320N Atomic Absorption Spectrophotometer can be used to measure constant quantity and trace metal elements in various samples through atomic absorption analysis and flame emission analysis by flame method, graphite furnace method and hydride method.Feature:Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentrationHigh energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.Parameter:ModelAA320NWavelength range190-900nmWavelength accuracy≤±0.5nmWavelength repeatability≤0.3nm (single direction)Spectrum bandwidth0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nmResolution<40%base line stability±0.004Abs/30minCharacteristic concentration of copper≤ 0.04μg/ml/1%Detection limit of copper≤0.008μg/mlBackground calibration abilityGreater than 30 timesRS232includingPrinteroptionalPower supply220V 3A, 50HzG.W.160Kg65KgPackage Dimensions1220x770x730mm (Main instrument)800x400x900mm ( Accessories )Options:1. Graphite Furnace Autosampler2. HGA graphite furnace system3. Hydride generator4. Hollow cathode lamp5. Graphite tubePC controlled Fully Automatic Flame and Graphite Furnace Atomic Absorption SpectrophotometerThe AA-4530F atomic absorption spectrophotometer is a single-beam instrument, equipped with a PC and dedicated programs for function controlling and data processing, for testing macro, micro and trace metal elements and semimetal elements.FeatureCompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lampPosition adjusting: the best height of the flame burner and can automatically set the front and rear positionsFully automated wavelength scanning and peak searchingComplete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameoutDeuterium lamp and self-absorption background regulationData processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly calledMeasuring method: flame absorption method and emission methodResult printing: parameter printing, data result printing and diagram printingComplete automatic controlling systemWith the help of the software, the following can be easily achievedSelection of the element lampUp-down-front-rear adjustment of the lifterAdjustment of the optical energySelection of the slitDetermination of wavelength scanning and peak searchingSelection of the atomizerSetting of the background deduction methodControlling of the gas flowAutomatic flaming and flaming outSetting of the graphite furnace testing methodAdvanced graphite furnace temperature controlling technologyThe bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing dataThe fast heating capacity can improve the flexibility of the elements furtherUse the ordinary power source of 220V without need of dynamic power of 380VThe maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samplesThree grades adjustable gas flow can accustom to more application needs Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring errorSafe, reliable and convenient flame system Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easilyEfficient Atomization system enables a higher sensitivityThe whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage.Multi-functional software workstationA workstation that is supported WINDOWS XP/2000/NTThe rich menu brings great convenience to the use of customerConvenient conversion between different menus makes the operation more easilyVarious analytical correction methods provide the users more choicesBasic default parameter settings enable even the beginners can do the normal operationFlexible storage, editing and printing methods give the user largest supportInstrument configuration:Atomic Absorption Spectrophotometer 1pcAir compressor without noise 1pcPC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)ParameterWavelength range190 - 900nmSpectral bandwidthCan automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nmAccuracy of the wavelength±0.15nmReceptivity of the wavelength≤0.04nmbase line stability≤0.002A/30min (Cu)Characteristic viscosity0.02μg/ml/1% (Cu)Checking limit0.004μg/ml (Cu)Preciseness0.5%Grating1800 lines/mmIn flamerAll-metal titanium burnerAtomizerEffective glass atomizerLamp standEight lampsD2 background correction abilityWhen the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction methodSize and weight700mm×550mm×450mm 75KgPower source220V±22V ACFlame system Acetylene air burner:100mmNitrous oxide acetylene flame head:50mmIgnition dynamic baseline drift:≤0.006A/30min(Cu) Characteristic viscosity:≤0.025μg/ml/1%Related standard deviation of the accuracy:≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) Safety system:Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.Graphite furnaceThe highest temperature:3000ºCThe largest temperature rising speed:≥2000ºC/SCharacteristic quantity:Cd≤0.5×10-12g Cu≤0.5×10-11gAccuracy:Cu≤3% Cd≤3%Size and weight:550mm×450mm×300mm 65KgSafety system:Over current protection Low air pressure alarm / protection Low cooling water flow alarm/protectionPower source and power:220V±22V AC 7000W
举报收藏 0
更多>本企业其它产品
Egg Powder Making Machine Small Laboratory Spray Dryer Equipment for Milk Coffee Tea Laboratory Medical Analysis Equipment Tabletop UV-Vis Visible Spectrophotometer Price Egg Powder Making Machine Small Laboratory Spray Dryer for Milk Coffee Tea High Precision 0.001mm Resolution Thickness Testing Gauge Digital Ultrasonic Flaw Detectors Equipment in Physics Ultrasonic Washer 25kHz  33kHz  40kHz and 59kHz Sweep Frequency Cleaning Machine for Sale Cheap Ultrasonic Sonicator with LCD Display Used Milk Homogenizer Double Tower Double Distilled Water Distiller Machine
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报