3kw ~ 100kw Low Water Head Low Flow Rate Small Hydro Turbine Generator

 
 
单价 1.00 / Set对比
销量 暂无
浏览 74
发货 Chinahenanxinxiang
库存 1000Set
过期 长期有效
更新 2020-08-18 16:48
 
联系方式
加关注0

Henan WZX Import and Export Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: 3kw ~ 100kw Low Water Head, Low Flow Rate Small Hydro Turbine Generator Model NO.: SH Standard: Nonstandard Speed: Low Speed Type: Horizontal Hydro Generator Size: Small Output Type: AC Three Phase Transport Package: Plywood Box Origin: China HS Code: 850239000 Product Description Small Hydro Turbine Generator UnitIts mainly used in rural place or other place where grid not available easily. Water source selectionGenerally, the small hydro electric power plant is located at the place with water height difference, where the water in small river can be collected to turbine unit in the power plant by inlet pipe, and the runner of turbine unit will be pushed by water flow to drive generator and generate electricity. So, before installation of small hydro electric power plant the water head and flow rate of water source must be /confirm/ied, then the power capacity of turbine unite can be calculated based on it. Water head measurementGross water head means the vertical height difference between upstream and downstream of water source, which can be measured by the following methods generally. 1. It can be measured by pressure meter installed at the end of pipe, the pressure value measured after closing valve is gross water head. 2. Measure the water level difference between upstream and downstream by level gauge. 3. Measure by such technology method as GPS. Net water head, means the pressure which can be applied by turbine unit effectively. It can be measured by open the valve, where the pressure value showed on the pressure meter of inlet pipe during turbine working is net water head. Flow rate measurement1,Section areaFlow rate is section area by flow speed, and the section area A of water channel can be calculated by measuring width and depth of it. For more accurate measurement, the section area of water channel can be divided into small piece, measure the area of small pieces and then add them to get the total one. Measurement of flow speed, a piece of float goods can be throw on the water surface and measure the movement of it in a fixed period to calculate the movement in one second, which is the flow speed. 2,Volume methodCollect water by a water tank, measure the time t needed to fill the tank, weight the water inside the water tank W, and the flow rate Q can be got by W/t. The flow rate should be measured for many times to get average value, beside that, the flow rate changing in different season should also be taken into consideration. Power capacity calculationPower capacity of turbine unit can be calculated by the formula of .Among it, - power capacity(kW); - unit efficiency(general use 0.7 - 0.8); - water inlet efficiency(general use 0.80 - 0.95); - water density (use 1000kg/m3); g - acceleration of gravity(m2/s),(general use 9.8);H - water head(m),vertical height from water level of pond to install place;Q - flow rate(m3/s). , among it, A means the section area(m2), means the flow speed(m/s). Runoff turbine generatorBrief descriptionModel of NYR, runoff type, power of 0.6~200kw, water head 5~300m, flow rate 0.005~0.5m3/sec, voltage 110 / 220 / 380 / 480v, frenquency 50 / 60Hz, material of water or liquid similar with water on chemical or physical, and temperature no more than 50ºC . Runoff turbine unit was composed by turbine and generator, which was connected by coupling. The turbine was mainly composed by spiral case, runner, main shaft, seal, suspend frame, bearing and so on parts. During working, the flow will enter into spiral case from inlet pipe to entrance of turbine with the force of working water head to lash the runner, then the generator will work correspondingly by the driven of main shaft. There are two kinds of generator as permanent type and excitation type. The rotator of permanent generator is made by permanent magnet material, the general used ones are ferrite and rubidiumIron boron. Where the latter one has higher efficiency and longer service time. Excitation generator is divided into brush excitation and brushless excitation, where the brush excitation generator need to change carbon brush regularly. The excitation generator has excitation system that no additional device need to be added for electricity generation. All excitation generator from our company has AVR to get a stable output voltage. Horizontal runoff turbine unit has the following advantages. 1.The inlet and outlet of water is through pipe to facilitate installation, use and maintenance. 2.Turbine is separated from generator to easy repair and replacement of spare parts. 3.Turbine has separate 2~3 bearing, generator has 2 bearing along to have a reliable structure. 4.Turbine has independence lubrication system that the bearing can enjoy a longer service life.
举报收藏 0
更多>本企业其它产品
50kVA High Efficiency Generator Diesel / Gasoline / Natural Gas Generator 150L/S Flow 25m Head High Efficiency Centrifugal Water Pump 1t ~ 600t Electric Overhead Traveling Crane Spare Parts Hydro Power Plant Turbine Generator Use Spare Parts 5t Swl Beautiful Compact High Efficiency Electric Chain Hoist 1t ~ 20t High Efficiency Stable Electric Wire Rope Hoist Light Wheel Load High Efficiency Powerhouse Use Overhead Traverling Crane 65/10t Powerhouse Use High Efficiency Double Girder Overhead Crane
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报