33kv/72.5kv/145kv 50Hz/60Hz Outdoor Horizon-Rotating AC Disconnect Switch with 2 Poles and a Horizon

 
 
单价 3.00 / Pieces对比
销量 暂无
浏览 294
发货 Chinazhejiangningbo
库存 10000Pieces
过期 长期有效
更新 2020-08-20 10:10
 
联系方式
加关注0

Ningbo Hyuan Power Industry Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: 33kv/72.5kv/145kv 50Hz/60Hz Outdoor Horizon-Rotating AC Disconnect Switch with 2 Poles and a Horizontal Break for Pole Mounted Model NO.: GW5 Brand: Hemg Certification: ISO Structure of Operating: Electric Common Model: YR Switching Mode: Single Throw-in Run: Turn the Horizontal Series: Single-Stage Grounding: Single Ground Number of Poles: Unipolar Movement Mode: Vertical Rotary Type Grounding Mode: Grounding Operation: Electric Installation: Outdoor High-voltage Structure: Double-column Disconnector Type: High-voltage Trademark: HEMG Transport Package: Carton with Wooden Specification: 33KV/72.5KV/145KV Origin: China Product Description GW5- TYPE IMPROVED DISConNECT SWITCH1 General1.1 Designation of type and nameGW5-33KV/72.5KV/132KV type outdoor tripahse high-voltage ,horizon-rotating AC disconnect switch with 2 poles and a horizontal break. (following we called it GW5 Disconnect switch in short)1.2 GW5 Serial disconnectors match GB1985-2004 High-voltage alternating current disconnectors and earth switches,it satisfy IEC129(1984) High-voltage alternating current disconnectors and earthing switches,and IEC694(1980) ,High-voltage switchgear and controlgear.1.3 Product useThis product is used to cut off or connect a circuit without any load and to cut off high-voltage circuit with high-voltage electric device to be overhauled such as high-voltage bus, circuit breaker and so on.1.4 Product characteristicsGW5 Serial Disconnect switch are researched and developed by ourselves in the foundation of producing GW5 for 20 years. It has the following characteristics:a. They have plentiful models and high technical parameters and can applied widely. In addition, they are suitable for high position installation. The main knife not only match manual device (CS17 series), but also match electric device(CJ6).b. New contact fingers(U-shape)and bending-formed contactors are adopted, for contact finger and socket, the new current structure and the insulator contact finger spring can supply enough capacity of current. c. Full seal structure and oilless bearing are adopted and the transmission shaft , pin are made of stainless .All steel parts and standard parts are ZINC-plated. Seal structure and tinning braided strap can give higher antirust ability to connection socket ,main knife switch conductive tube and earth knife switch tube.d. The simple dependable mechanical moving way was adopted, the main knife switch increased limited switchin and switchoff to increase the operating credibility of product.e. New improved CS171V manual structure gives a higher capability in dust palliative, Watertightness and antirust.f. Full ZINC-plated steel foundation racks and vertical & level transmission levers are available for users to choose. 1.5 The product usage environment conditiona. The altitude does not exceed 2000 meters;b. The environmental climate is between -50ºC and +50ºC;c. The wind press should not be higher 700pa;d. The earthquake intensity can not be over 9 degrees;e. The thickness of ice should not be exceed 20mm;f. Pollution degree of environment should be in , , degree.g. The install place should have no easy combustible and explode easily dangerous, the chemistry decay and violent vibration.2.The product classification and technique parameter2.1 Classification2.1.1 According to VOLTAGE :40.5kv,72.5kv,126kv2.1.2 According to current: 630A,1250A,1600A,2000A.2.1.3 According to earth switch: earth-free, left earth, right earth and double earth.2.2 The main technique parameterTabe 1No.TYPERatedparameterGW5-40.5GW5-72.5GW5-1261Rated voltage kV40.572.51262Rated current A6301250160020006301250160020006301250160020003Disconnect witchgPeak withstand current(kA)508010010050801001005080100100Short-time withstand current (effective value) (kA)2031.540402031.540402031.54040Short-circuit keeping time (S)44type earth knifePeak withstand current(kA)25Short-time withstand current (kA)10Short-circuit keeping time (s)45type earth knifePeak withstand current(kA)100Short-time withstand current kA40Short-circuit keeping time(s)26Short time power frequency withstand voltage (effective value) (kV)To earth110185260Break tobreak1252003007Lightning impulse withstand voltage(effective value) (kV)To earth185350550Break tobreak2153856308Terminal static mechanical load (N)horizontallongitudinal100010001000100010001000horizontalcross750750750750750750 Vertical force1000100010001000100010009bus-transfer current switching by disconnectors in gis (A)50410001280160050410001280160050410001280160010Radio jamming degreeNot more than 2000μV11Mechanical life3000 times2.3structure characteristic parametersTabe 2No.TypeRatedparameterGW5-40.5GW5-72.5GW5-1261Rated current6301250160020006301250160020006301250160020002Break insulating distance at disconnect switch off (≥mm)40065010003Insulating distance of conductive part to earth (≥mm)4006509004Resistance of main circuit (≤μΩ)200150115902201551201002451701351105Tryphase Switchin SYNCHRonISM of main knife≤mm)58126Switchin time of distributing deviceCJ6:3.75±1s7Weight of single pole (kg)1251501601902002403. Structure of product GW5 Disconnect switch consists of 3 single- pole, operating device and transfer section. Each single-pole is of a "V" structure which consists of bottom ,bearing seat, support insulator, connector, left & right contactor , earthing static contactor and earth knife switch.For this disconnect switch, the main knife can not only match CS17 series manual operating device, but also match CJ6G electric operating device. Earth knife matches CS17 series manual operating device . CS17 series manual operating device is equipped with F9 type auxiliary switch or vacuum auxiliary switch .When manual operating device attach electromagnetic lock, valid electric chain lock will be effected among disconnect switch, earth switch and circuit breaker to avoid mistake operating.4. Operating principle 4.1 operating principle for main knife switch Operating device of GW5 disconnect switch is connected to the oscillating arm through a vertical transfer lever and connector. Synchronous action of 3-pole can be effected through oscillating arm pulling the 3 separate pole.When the device acting, a support insulator is driven to rotate ;another support insulator is driven to rotate through a lever in bottom shelf (leftright contactors are separately fixed on 2 support insulators). Then action of switchin and switchoff of the 2contactors can be effected. 4.2 Operating principle of earth knife switch The 3-pole earth knife are connected by 3-pole transfer lever. Principle axle of operating device is connected to the 3-pole transfer lever through vertical transfer lever ,contactor and a set of space 4-links bar. Switch in and switch off of earth knife can be effected through vertical transfer lever and space 4-links bar when the device acting. 4.3 Auxiliary switch in operating device is connected to principle axle of device. When action (switch in or switch off), related contact will be opened or closed, Then give signals of switch in or switch off.4.4 Mechanical lock-out of main earth knives When the main knife and the earth knife both attach manual operating device, Lock-out between disconnect switch and earth switch is effected through interlock board of the device. When closed the disconnect knife, the earth knife can not be closed ;When earth knife is closed, don't close the disconnect switch. 5. INSTALLATION AND DEBUGGING5.1 Opening package and check Check if quantity of package is right according to packing list before opening package. Contact our company in time if there is anything improper. When opening package, check all parts carefully according to packing list. If there is anything wrong, please contact our company , too.5.3 Checking after installation and debugging a. switch position for main knife and earth knife should be rightb. Insulator distance of breaks should conform to request in graph 2c. 3-pole synchronism of main knife should conform to request in graph 2d. Resistance of main knife circuit should conform to request in graph 2e. Check if auxiliary switches properly when device at closed position, contact (of auxiliary switch) 1-3, 5-7, 9-11, ETC, are normally open contacts; 2-4, 6-8, 10-12, ETC, are normally closed contacts.f. When main knives is equipped with electric device ,normal action (open and closed)should be effected at 85% and 110% rated voltageg. Mechanical lock-out of main knife and earth knife should be right5.4 Our company can provide full equipped joints and lever that don not need welding.6. WORKING DIRECTIONS6.1 In general cases, this is disconnect switch should be operated when all load of circuit is removed (circuit breaker in open position)6.2. When main knife is closed, earth knife can not be closed ;When earth knife is closed ,main knife can not be closed.REMARK: FASTENING TORQUE FOR BOLTSBOLTS OF STAINLESS STEEL DIAMETER(mm)FASTENING TORQUE(N·m)64.5811101912321678ZINC-PLATED BOLTS OF STEELDIAMETER(mm)FASTENING TORQUE(Nm)12581614020270244707. MAINTAINCE AND REPAIR When maintaining or repairing this disconnect switch ,pay attention to :a. Check if ceramic parts of disconnect switch are damaged, there is any loose at glue position , there is any loose and rusty at all fastening positionb. Measure resistance of circuit and check if there is a big change of it .Check if contacts can contact well.c. Check if position of all electric connectors and auxiliary switch is right.d. Check if all rotation parts can rotate smoothly. There must not be rustness and jamming.e. Check if there is any change of signal of all connectors in second circuit.f. If any abnormal happens in operating, manage to solve it and touch the producer as soon as possible.8. STORAGE If not in use in a long time, place it in ventilated and dry place with a 10-cm -high elevation.9. ATTACHED documentS9.1 Quality certificate9.2 Installation and operation instruction for GW5 disconnect switch.9.3 Installation and operation instruction for CJ6G electric device (if main knife is equipped with electric device, it is in the carton for device)9.4. Packing listOne copy of all above documents loaded in a special file packet10. ORDER NOTICE Please note clearly as belowa. Type specification and quantityb. Rated current and rated voltagec. Type and request of device to match main knife, type and request of device to match earth knife d. Voltage for electromotor, voltage for control coil and pair quantity of auxiliary contacts when using electric operation device.e. Pair quantity (main and earth knives) of auxiliary contacts when using CS17 series manual operation device and note clearly if electromagnetism lock should be equipped; Please note clearly for main knife or both main knife and earth knife .It is accepted as auxiliary switch that should be equipped without clearly note (4 open and 4 closed)f. Pollution degree of environment : , or degree. It is accepted as degree without clear note.g. Form of earthing: earth-free, left earth, right earth and double earth. It is accepted as right earth when noted only as single earthh. Earth knife type: type or type knife. It is accepted as type earth knife without clear note.i. We can supply steel shelf according to user's request, please note the heightj. Material for connection board: copper or aluminum .It is accepted as aluminum without clear note.k. Other special request except above should be noted clearly when ordering11. Our company reserve the right of modification about writings and Pictures. If there be a modify, Forgive and don't notify.
举报收藏 0
更多>本企业其它产品
6kv/12kv/15kv/24kv/38kv  50Hz/60Hz  Indoor 50Hz/60Hz PCM Protection and Control Vacuum/Sf6 Gas /Swit 33kv/72.5kv/145kv 50Hz/60Hz Outdoor Horizon-Rotating AC Disconnect Switch with 2 Poles and a Horizon 33kv/72.5kv/145kv 50Hz/60Hz Outdoor Hgis Compact Easy Gas Insulated Switchgear Combined of CB Ds CT 66kv Aereal Fault Indicator with Portable Remote Controlwith Remote Terminal Communication Unit with 6kv/12kv/15kv/24kv/38kv  50Hz/60Hz  Indoor 50Hz/60Hz PCM Protection and Control Vacuum/Sf6 Gas /Swit 33kv/72.5kv/145kv 50Hz/60Hz Outdoor Hgis Compact Easy Gas Insulated Switchgear Combined of CB Ds CT 66kv Aereal Fault Indicator with Portable Remote Controlwith Remote Terminal Communication Unit with
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报