2019 New Design Lab Fume Hood Manufacturer Lab Equipment

 
 
单价 面议对比
询价 暂无
浏览 213
发货 Chinaguangdongguangzhou
库存 1000
过期 长期有效
更新 2020-05-06 18:25
 
联系方式
加关注0

Guangzhou Penway Scientific and Technological Co., Ltd.

企业会员第5年
资料未认证
保证金未缴纳
详细说明
Product Name: 2019 New Design Lab Fume Hood Manufacturer Lab Equipment Condition: New Customized: Customized Color: Optional Hood Type: Standard Feature: Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof Function: Exhaust, Velocity Control Type: Bypass Type Material: Cold-Rolled Steel Trademark: PENWAY Transport Package: Wooden Package Specification: 1500*850*2350mm Origin: China HS Code: 940320000 Product Description 2019 new design lab fume hood manufacturer lab equipmentProducts Description:Structure:Made of thickness ≥1.2mm cold-rolled steel steel for the out layer, steel surface treated by acid-alkali-resistant and coated with epoxy resin powder. The inner layer is the anti-corrosion material.Lining:Lined with 5mm thick compact board (chemical resistant), segmented design, air flow pressure is maintained smoothly by teardrop-shaped baffle in accordance with aerodynamic principles.Working surface:Covered epoxy resin countertops or ceramic worktops with thickness ≥19mm, and the outer edge of not less than 25mm. The recessed 5mm inside disc design will collect splashes things. With high performance of anti-heat, chemical resistant.Visual Windows:Use 5mm tempered explosion-proof glass. lnternal uses of pituitary balancing device, can stay in any position during 0~900mm. Closure equipped with a rubber buffer.Lighting:Equipped with two (15W) LED energy-saving lamp. Lamp mounted on the top of hood and quarantined by the steam-proof glass cover inside the fume hood.Transmission:Windows Transmission system consists of a metal sprocket, plactis chains, synchronizing shafts and other devices. Balancing system prevents sash tilting and can be one- hand controlledSelection of the proper type of fume hood to use in a laboratory should be based upon two interrelated considerations:1:The hood must allow the user to perform the work in a safe, efficient manner.2. The need to reduce air conditioning cost. The interior of the Penway`s hood resists the corrosive effects of chemicals. The hood under structure should provide for storage of the required chemicals for the work being done in the hood. The total cost of a hood is greatly affected by its exhaust air requirements. The annual cost of heating and cooling the air exhausted by the hood can be as high as the initial cost of the hood itself.Choosing the proper hood type and sash configuration can significantlyreduce these costs.High Performance Fume HoodsPenway High-Performance/Low-Flow Fume HoodsCompared to most traditional fume hoods, these high performance, low flow hoods are safer, have lower installation costs, and are up to 50% less expensive in operating costs.We have designed and installed fume hoods in labs around the world.High performance fume hoods has a series of design features to provide unsurpassed containment and operator protection:1:Engineered baffle system provides proper air distribution2:Constant air velocity (variable air volume) reduces energy use relative to sash position3:Rounded corners at hood entrance reduce turbulence, improving efficiency4:Aerodynamic sash pull5:Containment trough with directional vanes and white Plascote finish adds durability and chemical resistance6:Cord pass-through lets sash fully close without appliance cords getting in the way7:Lower entrance safety bar provides a personal safety barrier880mm high viewing area8:White ResChem interior with vapor-proof fluorescent light.9:458mm vertical opening with keyed sash stop to access 685mm set-up position10:Double-wall construction for installation of plumbing and electrical service fixtures.Advantages of High Performance Chemical Fume Hoods:1:Engineered to exhaust 50% less conditioned air from the laboratory2:Designed to capture fumes while working in today's modern laboratories with varying factors such as lab traffic, fluctuating temperatures and interior hood loading3:Fume capture and containment can be demonstrated with tracer gas testing5:Standard, available for all new chemical fume hood installations6:Quiet operation7:Low airflow provides an ideal environment for working with powders and delicate work.Low-flow/high-performance hoods use substantially less energy to operate over the lifetime of the fume hood exhaust system. Visit Laboratory Fume Hood Energy Model to calculate your energy needs.Penway has our own HVAC engineers to design the lab fume hood ventilation. From lab ventilation designs to construction, until system test and accept of work. Penwaycan provide one-stop service to customer.
举报收藏 0
更多>本企业其它产品
Mobile Cabin PCR Lab Equipment Energy Saving Chemical Resistant Fume Hood with Ce Certificate. School Lab Furniture Physics Laboratory Table Steel Lab Furniture Equipment Lab Table with Reagent Shelves Chemistry Laboratory Table Phenolic Epoxy Resin Worktops Full Steel Painted Laboratory Filing Cabinet Storage Cabinet Durable Chemical Resistant Physics Chemistry Lab Furniture Science Lab Bench
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报