(MS-300P) Portable First-Aid Medical Equipment Automatic External Defibrillator (AED)

 
 
单价 499.00 / Piece对比
销量 暂无
浏览 197
发货 Chinajiangsunanjing
库存 100000Piece
过期 长期有效
更新 2020-05-06 21:59
 
联系方式
加关注0

Medical Sources Co., Limited

企业会员第4年
资料未认证
保证金未缴纳
详细说明
Product Name: (MS-300P) Portable First-Aid Medical Equipment Automatic External Defibrillator (AED) Model NO.: MS-300P Type of Operating Light: Portable Anesthesia: Semi Open Suction Source: Oxygen LCD Display: With LCD Display Group: Adult Certification: CE, ISO13485 Kind: External Biphasic Defibrillator Type: Defibrillator G.W: 1.5 Kg N.W: 1.2 Kg Trademark: customized Transport Package: 1 Piece in Carton Specification: 303 x 216 x 89mm Origin: China HS Code: 9018193010 Product Description MS-300P Portable Aed Automatic External DefibrillatorFeatures:Color Screen size:3.5"Automatic Self-testingBiphasic Energy OutputCPR MetronomeCPR Coaching (Optiona)Adult and Pediatric DefibrillationExtensive Voice and sisual promputs DefibrillatorCategorySpecificationOutputBiphasic Truncated exponentialEnergy Sequence(adult )150/150/200(Default)150/200/200200/200/200Note: the Energy sequence can be changed using the computer IR port.Energy Sequence(Pediatric)50/70/85(Default)70/70/8570/85/8585/85/85Note: the Energy sequence can be changed using the computer IR port.Charge Time10 sec. to 200 JAnalysis Time9 sec.The maximum time from the initiation of rhythm analysis to readiness for maximum Energy discharge after 15 shocks.Less than 30 secondsThe maximum time from initially switching power on to readiness for maximum Energy discharge after 15 shocks..Less than 35secondsAudible prompts19 audible promptsVisual promptsLED/LCDControlssix buttons - On/Off, Shock, and 4 software-configurable buttonsOutput Energy Accuracy±15% into any impedance from 25 to 175ΩThe Maximum Voltage1800±20VOutput disabled when the PATIENT impedance is outside limits20Ω to 200ΩRecovery of the ECG input after defibrillation<10sthe time from switching "ON" until the unit is ready for NORMAL USE,<4she time required for the ME EQUIPMENT to warm from the minimum storage temperature between uses (4.2.1) until the ME EQUIPMENT is ready for its INTENDED USE when the ambient temperature is 20 °C>30minhe time required for the ME EQUIPMENT to cool from the maximum storage temperature between uses (4.2.1) until the ME EQUIPMENT is ready for its INTENDED USE when the ambient temperature is 20 °C>1min
举报收藏 0
更多>本企业其它产品
(MS-300A) Medical Hospital Emergency First Aid Portable Aed Biphasic Automatic External Defibrillato (MS-500) 5L Medical Equipment Low Noise with High Pressure Oxygen Concentrator (MS-300A) Medical Hospital Emergency First Aid Portable Aed Biphasic Automatic External Defibrillato (MS-300A) Medical Hospital Emergency First Aid Portable Aed Biphasic Automatic External Defibrillato (MS-1212) LCD Patient Monitor 12 Channels Twelve Channel ECG (MS-800A) LCD Display Fetal Detector Monitor Fetal Doppler Monitor (MS-390D) Multi-Used Portable Automatic External Defibrillator
网站首页  |  关于我们  |  联系方式  |  用户协议  |  隐私政策  |  版权声明  |  网站地图  |  排名推广  |  广告服务  |  积分换礼  |  网站留言  |  RSS订阅  |  违规举报